Tandberg Data
Inquiry
9-7
Tandberg SLR Product Line SCSI Functional Specifications
9.3.2.2.
Unit Serial Number
BYTE
BIT 7
6
5
4
3
2
1
0
00
Peripheral Qualifier
Peripheral Device Type
01
Page Code = 80h
02
RESERVED
03
Page Length = 0Ch
04
Unit Serial Number
05
06
07
08
09
10
11
12
13
14
15
End of String = 00h
Table 9-4: Unit Serial Number Page
Peripheral Qualifier
This field will normally be set to zero. When an
Unsupported LUN condition exists ( If an IDENTIFY
message is received, the LUN field in the Command
descriptor block will be ignored and only the LUN field
in the IDENTIFY message will be evaluated. ), this field
will, however, be set to 3.
Peripheral Device
Type
This field is normally set to 1. When an Unsupported LUN
condition exists , this field will, however, be set to
1Fh.
Page Code
This field will be set to the value of the Page Code
field in the Command Descriptor Block.
Page Length
This field specifies the length in bytes of the
parameters that follow the Page Length field.
Unit Serial Number
This is the unit serial number represented with 11 ASCII
characters. The string is terminated with a zero (00h)
character.