Tandberg Data
Mode Sense
15-7
Tandberg SLR Product Line SCSI Functional Specifications
15.3.5. Control Mode Page
See the MODE SELECT command for details on the current,
saved and default values of this page (Page Code 0Ah)
The PS bit will be set to zero for this page.
The Changeable Values page will return the following
values:
Byte 00 : 0Ah
Byte 01 : 0Ah
Byte 02 : 01h
The RLEC bit is changeable
Byte 03 : 00h
Byte 04 : 00h
Byte 05 : 00h
Byte 06 : 00h
Byte 07 : 00h
Byte 08 : 00h
Byte 09 : 00h
Byte 10 : 00h
Byte 11 : 00h
15.3.6. Data Compression Page Descriptor
See the MODE SELECT command for details on the current,
saved and default values of this page (Page Code 0Fh)
The PS bit will be set to one for this page.
The Changeable Values page will return the following
values:
Byte 00 : 8Fh
Byte 01 : 0Eh
Byte 02 : 80h
The DCE bit is changeable
Byte 03 : E0h
The DDE bit and the RED field is changeable
Byte 04 : FFh
The Compression Algorithm is changeable
Byte 05 : FFh
Byte 06 : FFh
Byte 07 : FFh
Byte 08 : FFh
The Decompression Algorithm is changeable
Byte 09 : FFh
Byte 10 : FFh
Byte 11 : FFh
Byte 12 : 00h
Byte 13 : 00h
Byte 14 : 00h
Byte 15 : 00h