Tandberg Data
Log Sense
13-36
Tandberg SLR Product Line SCSI Functional Specifications
13.3.8. Tape Mark Counters Page
BYTE
BIT 7
6
5
4
3
2
1
0
00
RESERVED
Page Code = 32h
01
RESERVED
02
Page Length = 0010h
03
04
Filemark Counter Parameters
11
12
Setmark Counter Parameters
19
Table 13-33: Tape Mark Counters Page
Page Code
The Page Code for this page is 32h.
Page Length
This field is set to 0010h indicating that the page
parameters occupy 16 bytes.
Filemark Counter Log Parameters
BYTE
BIT 7
6
5
4
3
2
1
0
n+0
Parameter Code = 0000h
n+1
n+2
DU
DS
TSD
ETC
TMC
R
LP
n+3
Parameter Length = 04h
n+4
Filemark Counter
n+7
Table 13-34: Filemark Counter Log Parameters
Parameter Code
The Parameter Code is set to 0000h.
DU
A Disable Update (DU) bit set to 0 indicates that the
Drive is free to update the counter.
A DU bit set to 1 indicates that the Drive shall not
update the counter except in response to a LOG SELECT
command that specifies a new value for the counter.
The initiator may use the LOG SELECT command to set or
clear the DU bit.
The Drive will set the DU bit to 1 when the counter
reaches its maximum value (FFFFFFFFh).
DS
The Disable Save (DS) bit is set to 1 to indicate that
the Drive does not support saving of this log parameter.
(Note: This bit can not be changed by the initiator)