Tandberg Data
Mode Sense
15-8
Tandberg SLR Product Line SCSI Functional Specifications
15.3.7. Device Configuration Parameters Page Descriptor
See the MODE SELECT command for details on the current,
saved and default values of this page (Page Code 10h)
The PS bit will be set to one for this page.
The Changeable Values page will return the following
values:
Byte 00 : 90h
Page Code
Byte 01 : 0Eh
Page Length
Byte 02 : 40h
The CAP bit is changeable
Byte 03 : FFh
The Active Partition field is changeable
Byte 04 : 00h
Byte 05 : 00h
Byte 06 : FFh
The Write Delay Time is changeable
Byte 07 : FFh
Byte 08 : 10h
The AVC bit is changeable
Byte 09 : 00h
Byte 10 : 00h
Byte 11 : 00h
Byte 12 : 00h
Byte 13 : 00h
Byte 14 : 01h
The RFTD bit is changeable
Byte 15 : 00h
15.3.8. Medium Partition Parameters Page Descriptor
See the MODE SELECT command for details on the current,
saved and default values of this page (Page Code 11h)
The PS bit will be set to zero for this page.
The Changeable Values page will return the following
values:
Byte 00 : 11h
Byte 01 : 4Eh
Byte 02 : FFh
The Maximum Additional Partitions is changeable
Byte 03 : FFh
The Additional Partitions Defined is changeable
Byte 04 : B8h
The FDP, IDP and PSUM fields are changeable
Byte 05 : 00h
Byte 06 : 0Fh
The Partition Unit is changeable
Byte 07 : 00h
Byte 08 : FFh
The Partition Size Descriptor 0 is changeable
Byte 09 : FFh
The Partition Size Descriptor 1 is changeable
...
Byte 78 : FFh
The Partition Size Descriptor 34 is changeable
Byte 79 : FFh
The Partition Size Descriptor 35 is changeable