If you are
not
using an EC-8 Consolidator, simply enter special codes *14*3*, *18*5*, and *55*, each
followed by an acknowledgement beep, to activate the MODE III on the Talkaphone unit.
If you are using an EC-2 Consolidator on a PBX, you should enter special codes *14*3*, *18*5*, and
*55*, each followed by an acknowledgement beep, to activate the MODE III on a Talkaphone unit. An
EC-2 consolidator does not have to be programmed.
Remember, the Talkaphone unit requires a primary phone number to operate correctly. If you are using
it with a PBX in "hot line" or "ringdown" mode, enter the phone number as *13*1234567* if used with a
consolidator, or *13*12345* if no consolidator is used. Also enter *40*0* in addition to MODE II or
MODE III commands.
Auxiliary Circuits
The Auxiliary Input allows you to activate the unit via remote devices that use a dry contact closure,
such as Model SA-1 Scream Alert, an elevator emergency stop button, a sensor for a stuck elevator or
open elevator door, smoke detector, alarm switch, etc. When the device is activated, the
Emergency/Information Phone will automatically call out and establish full communication.
To use the auxiliary input feature, contact Talkaphone to request an ETP-AUXIN-KIT at no
charge.
The Auxiliary Outputs allow you to remotely activate two different functions, such as turning on a siren,
light, or CCTV camera, opening a door, etc. In addition, Auxiliary Outputs can be programmed to
automatically activate a strobe, siren, or CCTV when the call button on the unit is pushed. This is
particularly useful when the unit is being used with a strobe light in parking facilities, campuses, and
access control applications. The auxiliary outputs are rated at a maximum of 50 mA at 30V DC or AC.
Intelli-Voice
All ETP-500 Series Analog Call Stations have Intelli-Voice.
This recorded message will automatically be heard by the party receiving the call as soon as they
answer. Immediately thereafter, two-way conversation will occur. If you wish the message only to be
heard upon command by the receiving party, enter *70*. The message will then be heard only if the
receiving party enters *59* after receiving a call. The message can be repeated as many times as
desired by using this command.
The recording can be made at the same time that other programming is done and can be changed at
any time by calling the unit, entering the Guard Code, and recording a new message. This feature
operates independently of the DTMF transmission of the unique identifier, which can either be active or
suppressed as desired.
Two Button Models (ETP-500EI, ETP-500EI3)
Each button on the two-button Phone works just as on a single-button Phone. However, the red
Emergency button on a two-button Phone always takes priority over the lower black button. If the upper
Emergency button is pressed while a conversation is taking place via the lower black information
button, the first call will automatically be disconnected and the emergency call will immediately be
placed.