dataplate is the same as the mains voltage.
For 12 Volt devices only:
The product must be powered by 12 V of direct current.
If a battery is used, this must have a minimum capacity of 60
Ah and it must be able to dispense a current of at least 30A
continuously. If a power supply is used, this must be able to
deliver at least 30 Amperes and have an adequate insulation
between input and output. The red and black clamps can be
connected randomly at the positive or negative poles. Do not
use the product using a damaged battery or power supply
which is damaged.
Maintenance must be carried out by a qualified technician,
in compliance with manufacturer’s instructions and local
safety regulations.
Disconnect the power and wait for the appliance to cool
down before servicing, repairing and cleaning.
If the power cable is damaged, request a substitute from the
producer, technical assistant or other qualified personel to
avoid danger.
Grounding is compulsory. Connect appliance to an effective
ground (except for the 12 Volt model)
Do not pull the power supply cord to disconnect it from
outlet.
Do not touch the appliance with any wet part of the body
and do not operate it when barefoot.
Be sure that the electrical cords of other appliances do not
touch hot parts of the appliance.
Do not expose the appliance to atmospheric agents.
If the appliance, especially the handle, becomes hot due to
direct exposure to sunlight, move it to the shade.
During it’s use, the electrical power supply system and the
OXALIKA vaporizer must be arranged at an adequate
distance from flammable materials. Pay special attention to
the electric arc that is formed during the linking of the
power cables to the poles of the power supply system.
Do not use the product in case that parts of the device are
damaged.
7. To reduce the risk of burns
.The dispenser tube [9] the resistance [12] and
the thermostat [11] reach temperatures of around 200-220
°C and therefore may cause burns. Do not touch the
indicated parts and wear suitable protective gloves to
protect against accidental contact.
The other parts of the vaporizer with the exception of the
handle [8], the knobs [1] [6] and the process caps [11] can
reach temperatures of about 90-100 ° C. The risk of burns is
particularly present. Wear suitable protective gloves before
touching hot parts.
Ensure that nobody touches the device when it is hot.
After switching off the appliance remains hot for several
minutes.
Do not allow clothes or other flammable materials to come
in contact with hot components of the appliance until they
have cooled down.
8. To reduce the risks caused by
exposure of oxalic acid:
Do not use in closed spaces
Use only in open spaces in a well ventilated area.
Do not breathe in vapours or oxalic acid powder.
Wear a whole body protection suit to avoid contact with
vapours or oxalic acid powder, both when filling up the tank
and also during treatments.
Pay special attention to the handling of the oxalic acid.
Avoid direct contact of the oxalic acid with
eyes, skin and respiratory tract.
Wear saftey glasses.Follow the instructions in
product designated manual.
Wear saftey gloves.
Follow the instructions in user manual.
Wear a protective mask for respiratory tract with
ABE/P3 filter or higher.
Follow the instructions in product user manual.
Be aware of wind direction during treatment so that the
oxalic acid is not blown in the direction of anybody,
including the person carrying out the treatment.
The treatment of bee colonies should happen only outside in
open spaces. During and after the treatment ventilate the
hive well, nobody should remain in the apiary.
After the treatment, especially the winter treatment when
the bees don’t clean like in summer, there may be some
oxalic acid crystals inside the hive and on the bottom board.
Be careful and wear protective gear.
Maintain the oxalic acid in it’s original packaging and in a
safe place (with label in accordance with the law)
As a precaution- wash hands well after use.
IN CASE OF INGESTION
:
Contact an Antivenom centre or a doctor.
IN CASE OF CONTACT WITH EYES
:
Wash carefully for a few minutes. Remove contact lenses and
keep washing and rinsing.
IN CASE OF CONTACT WITH SKIN
:
Wash thoroughly with water and soap.
9. To reduce the risk of injury or work related accidents and
illnesses other than those described previously:
Do not use the device in dim lighting conditions. In case, use
artificial light.
Clean the device exclusively with water and avoid water
entering the handle and coming into contact with the
thermic insulation .
The use of the product by professional operators that use it
frequently, must be aware of factors that could increase the
risk of danger to the operators themselves.
Do not leave the device unattended when it is switched on.
Do not leave the device nor the oxalic acid in places
frequented by children and/or where children could reach.
Handle the device exclusively through the handle[8] , the
knobs [1] [6] , the hammer [7] and the caps [2], and the
doser caps [10].
For further information on the use of oxalic acid, please
refer to the technical and saftey manual of the oxalic acid
itself.
Considering the nature of the device, and its intended use,
the dangers that derive specifically with the use of the
OXALIKA PRO vaporizer are added to the dangers involved
in beekeeping . Faced with these dangers, the professional
user will have to remedy after appropriately evaluating
them as per applicable laws.
10.
To reduce the risk of damage
The dispenser tube [9] reaches temperatures of approximately
200 °C and therefore could damage parts of the hive that come
into contact with it. Do not use on hives made of plastic or on
EN