Maintenance and Care 7
TW9
87
7.9.9 Hydraulic oil tank
Checking hydraulic oil level
•
Check the oil level using the oil dipstick (51/1);
top up hydraulic oil if required.
Changing the hydraulic oil
Danger of scalding when hot oil is
drained!
•
Retract all hydraulic cylinders.
•
Stop the engine.
•
Unscrew the oil dipstick (51/1).
•
Remove the drain plug (51/4) on the hydraulic
oil tank and drain oil into a clean receptacle.
Collect the waste oil, do not allow it
to seep into the ground.
Dispose of according to
regulations!
•
Flush and clean the hydraulic tank as required
(to do so, completely remove the suction filter
51/2).
•
Screw back on the drain plug carefully.
•
Fill up with clean hydraulic oil using the
breather. To do so, remove the filter head
(51/3).
•
Screw back on the breather head.
•
Screw back in the oil dipstick.
L834-051
3
1
2
4
Fig. 51 Hydraulic oil tank