About this Product
--------------------------------------------------------------------------------------
8
Rear Panel
※
Rear panel diagram of ZX-S-400LAN
.
Series Operation Control Connectors
(
ZX-S Series Type-LAN)
Connector for series connections.
When using the Slave unit, connect with the Master unit’s
minus output terminal using wires.
.
External Control Connector
(
ZX-S Series Type-LAN)
Connectors for the external analog control, analog monitor
output, and status/alarm output.
Use the included specialized connectors.
.
Fan Motor
Cools the device internally.
The fan motor’s rotation speed will change in response to
the output power and output current.
.
DC OUTPUT
Output Terminal
Direct Current Output Terminal
A Crimp-Style Terminal must be used. Please be sure
to tighten all attachment screws.
After connecting, attach the output terminal cover
before use.
.
LINE INPUT
Input Terminal
Inlet connector connects power to the device.
Use the included input power cable.
The nominal voltage for the power supply is indicated on the
rear panel.
Please use only the input power cable that is included.
Do not use the included input power cable with any other
products.
.
SENSE
Sensing Terminal
Terminal for Remote Sensing
.MNT
MNT Switch
Swicth for the maintenance to rewrite F/W.
Do not operate the switch during working. If operate, the
product may not work normally.
.
LINK/ACT
LINK/ACT Lamp
Lamp to indicate the status of LAN connection
establishment and the communication status.
LINK:Lights at LAN connection establishment.
ACT:Blinks in the status of data communication.
.
LAN
Connector for LAN Communication
Connector to connect to computer etc. by LAN
communication cable (cross).
.
SERIAL I/F
Multi-Channel Connectors
Connectors for when controlling multiple ZX series units
or for controlling RS-485 type, serial ports.
Connect using KXC-300 (300mm) cable.
.
TERMINATION
Parallel Operation Control (Output)
Termination Resistor ON/OFF Switch
Sets the termination resistor settings.
When controlling one ZX series power supply via serial
port, please set the toggle switch to ON.
When using 2 or more power supplies, please set the first
and last ZX series DC power supply units’ termination
resistor ON/OFF switch to ON. (For all other units, set
to OFF)
!
!
26
L
AN
S
ER
IA
L
T
ER
MI
N
AT
IO
N
OFF
ON
IN
OUT
M
/
S
C
ON
T
RO
L
SEN SE
+
D C OU T PU T
-
+ -
100-240~,50/60Hz,7A MAX
L IN E I NP UT
27
28
29
30
33
34
35
36
37
25
A
CT
L
IN
K
M
NT
32
31
Summary of Contents for ZX-S-LN Series
Page 1: ...Constant Voltage Constant Current DC Power Supply series Instruction Manual...
Page 13: ...About this Product 10 This is blank page...
Page 63: ...Useful Function 60 This is blank page...
Page 151: ...Controlling with External Analog Contact Signals 148 This is blank page...
Page 157: ...Special Loads 154 This is blank page...
Page 199: ...Specifications 196 This is blank page...
Page 200: ...197 External Diagrams ZX S 400LN 400LAN 4 M3...
Page 201: ...Appendix 198 ZX S 800LN 800LAN...
Page 202: ...Appendix 199 ZX S 1600LN 1600LAN...