About this Product
------------------------------------------------------------------------------------
5
Part Names and Functions
Front Panel
①
.
STEP VOLTAGE/CURRENT
Setting/Selection Dial
Selects the voltage, current, OVP, OCP settings and
various other parameters. Press the dial to change the
settings number place.
②
.
MEMORY
Memory Display/Settings Key
Saves and loads the panel settings with keys
“A”,”B”,and “C”. Also, depending on the Function item
setting, this can be used to select One-Action or Two-
Action loading method.
③
.
OUTPUT
Output ON/OFF Toggle Key
Toggles output ON/OFF.
The factory default setting for the output, after inserting
power, is OFF.
④
.
Output ON/OFF Display Lamp
Lights when the output is set to ON.
⑤
.
LOCAL
LOCAL Key
Switches between “LOCAL”, operated from the panel,
and “REMOTE”, operated by control via serial data
communication.
※This is the front panel of the ZX-S-800LN
⑥.LOCK
LOCK Key
Locks panel from use.
Below are the 3 types of Lock settings. Each function
setting key (FUNC.) can be changed.
・Locks everything but the LOCK key
・Locks everything but the OUTPUT and LOCK key
・Locks only the Voltage/Current Dial, PRESET, and
FUNC. keys.
⑦.FUNC.
Function Key
Used for setting various functions
⑧.POWER
Input Power Switch
Toggles power ON/OFF
⑨.Ventilation Panels
Panels which allow cool air to enter and cool the
product internally.
OUTPUT
PRESET
OVP
OCP
POWER
FUNC.
LOCAL
LOCK
DISPLAY
A
B
C
STORE
MEMORY
CC
CV
OUTPUT POWER (%)
STEP
CURRENT
STEP
VOLTAGE
PRESET FUNC. REMOTE LOCK
ALARM RESET
20
60
100 LMT
40
80
DC OUTPUT
+
-
80A MAX
7
8
1
2
3
4
5
6
9
N
Summary of Contents for ZX-S-LN Series
Page 1: ...Constant Voltage Constant Current DC Power Supply series Instruction Manual...
Page 13: ...About this Product 10 This is blank page...
Page 63: ...Useful Function 60 This is blank page...
Page 151: ...Controlling with External Analog Contact Signals 148 This is blank page...
Page 157: ...Special Loads 154 This is blank page...
Page 199: ...Specifications 196 This is blank page...
Page 200: ...197 External Diagrams ZX S 400LN 400LAN 4 M3...
Page 201: ...Appendix 198 ZX S 800LN 800LAN...
Page 202: ...Appendix 199 ZX S 1600LN 1600LAN...