Geniox Air Handling Unit - User Manual | 3060386
Note:
Special sizes of filters and MERV ratings are available from Camfil.
M.4.1
Bag filters
Turn the unit off and wait for 2 minutes until unit completely stops. Used filters can be pulled out. Store the used filters immediately in
plastic bags to avoid polluting the environment with dust particulates. Geniox units in the sizes 15 – 25 are provided with a very corro-
sive-resistant and reliable system, where filters are slid into the units in a lower and upper durable U-profile of plastic/rubber. Check the
upper and lower U-profile for damage and check the vertical rubber profile on the back wall as well as the rubber profile on the inspec
-
tion door for damage. The new filter bags must be pushed carefully into the unit in order to ensure that they are sealed properly. The
filters must have vertical bags.
Bag filters are available in MERV 9 and 14 rating. Other MERV ratings can also be ordered. Bag filters are 15 inch deep.
Panel filters are available in MERV 8 and 13 ratings. Other MERV ratings can also be ordered.
2 inch deep panel filters are available as a standard option. 4 inch deep panel can also be ordered.
ONE self-adhesive foam strip must be placed on the vertical
frame of EACH filter to avoid major air leakage through the
vertical opening between 2 filters. Please note – only ONE self-
adhesive foam strip must be placed on the vertical frame of EACH
filter – Please establish the practical rule that the self-adhesive
foam strip is placed on the vertical side that is visible from the
inspection side. These very important self-adhesive foam strips
are usually not delivered by the suppliers of filters. The customer
must order the self-adhesive foam strip from a supplier of foam
strips. Width of the foam strip is about 9/16” (15 mm) and
thickness of foam strip must be exactly 5/16” (8 mm). If the
thickness of the foam strip is less than 5/16” (8 mm), there will
be a gap for leakage between the filters. If the foam strip is more
than 5/16” (8 mm) the row of filters in the U-profile will be too
wide making it impossible to close the inspection door.
Note! The
staff must have the self-adhesive foam strips available when
they go to the air handling unit. Without those self-adhesive
foam strips, any change of filters is impossible.
Remove the protection from the self-adhesive side of the strip.
38
| Adjustment and maintenance operations
Summary of Contents for Geniox 10
Page 2: ...Geniox Air Handling Unit User Manual 3060386...
Page 6: ...Geniox Air Handling Unit User Manual 3060386...
Page 35: ...3060386 Geniox Air Handling Unit User Manual Star up adjustments use and commissioning 29...
Page 61: ...3060386 Geniox Air Handling Unit User Manual ERW maintenance 4 8...
Page 62: ...Geniox Air Handling Unit User Manual 3060386 5 1 Roof curb master tables...
Page 63: ...3060386 Geniox Air Handling Unit User Manual Roof curb master tables 5 2...
Page 64: ...Geniox Air Handling Unit User Manual 3060386 5 3 Roof curb master tables...
Page 65: ...3060386 Geniox Air Handling Unit User Manual Roof curb master tables 5 4...
Page 66: ...Systemair NA 8 Rouse Street Tillsonburg ON N4G 5W8 Toll free 800 688 6363...