1 - 7
1 Introduction to the NA-series Programmable Terminals
NA-series Programmable Terminal Hardware User’s Manual (V117)
1-4 S
p
ecific
ation
s
1
1
-4-1
Gene
ral S
pecifications
1-4
Specifications
This section gives the hardware specifications of the NA-series PTs.
1-4-1
General Specifications
Item
Specification
NA5-15W
NA5-15U
NA5-12W
NA5-12U
NA5-9W
NA5-9U
NA5-7W
NA5-7U
Rated supply
voltage
24 VDC
Allowable power
supply voltage
range
19.2 to 28.8 VDC (24 VDC
±
20%)
Allowable
momentary
power interrup-
tion time
Operation for momentary power interruption is not specified.
Power con-
sumption
47 W max.
45 W max.
40 W max.
35 W max.
Ambient operat-
ing temperature
0 to 50
°
C
*1*2
Ambient stor-
age temperature
−
20 to 60
°
C
*3
Ambient operat-
ing humidity
10 to 90%
*2
Must be no condensation.
Atmosphere
Must be free from corrosive gases.
Pollution degree
2 or less: JIS B 3502, IEC 61131-2
Noise immunity
2 kV on power supply line (Conforms to IEC 61000-4-4.)
Vibration resis-
tance (during
operation)
Conforms to IEC 60068-2-6.
5 to 8.4 Hz with 3.5-mm half amplitude and 8.4 to 150 Hz with 9.8 m/s
2
for 100 minutes each
in X,Y, and Z directions (Time coefficient of 10 minutes × coefficient factor of 10 = total time
of 100 min.)
Shock resis-
tance (during
operation)
Conforms to IEC 60028-2-27.
147 m/s
2
3 times each in X, Y, and Z directions
Dimensions
420
×
291
×
69 mm
(W
×
H
×
D)
340
×
244
×
69 mm
(W
×
H
×
D)
290
×
190
×
69 mm
(W
×
H
×
D)
236
×
165
×
69 mm (W
×
H
×
D)
Panel cutout
dimensions
392
×
268 mm
(horizontal
×
vertical)
Panel thickness: 1.6
to 6.0 mm
310
×
221 mm
(horizontal
×
vertical)
Panel thickness: 1.6
to 6.0 mm
261
×
166 mm
(horizontal
×
vertical)
Panel thickness: 1.6
to 6.0 mm
197
×
141
mm
(horizontal
×
vertical)
Panel thickness: 1.6 to
6.0 mm
Weight
3.2 kg max.
2.3 kg max.
1.7 kg max.
1.3 kg max.
Degree of pro-
tection
Front-panel controls: IP65 oil-proof type, UL Type 4X (at initial state)
To reinstall the NA Unit in a panel, contact your OMRON representative for replacement of
the rubber packing.
Battery life
Battery life: 5 years at 25
°
C
The RTC will be backed up for 5 days after the battery runs low. The RTC will be backed up
by a super capacitor for 5 minutes after removing the old battery.
(This assumes that the power is first turned ON for at least 5 minutes and then turned OFF.)
+1
0
+1
0
+1
0
+1
0
+1
0
+1
0
+0.5
0
+0.5
0
Summary of Contents for OMRON NA Series
Page 8: ...Sections in this Manual 6 NA series Programmable Terminal Hardware User s Manual V117...
Page 12: ...CONTENTS 10 NA series Programmable Terminal Hardware User s Manual V117...
Page 34: ...Revision History 32 NA series Programmable Terminal Hardware User s Manual V117...
Page 82: ...3 Installation and Wiring 3 22 NA series Programmable Terminal Hardware User s Manual V117...
Page 164: ...5 Troubleshooting 5 18 NA series Programmable Terminal Hardware User s Manual V117...
Page 179: ...I 1 I NA series Programmable Terminal Hardware User s Manual V117 Index...
Page 181: ......