4 - 15
4 System Program
NA-series Programmable Terminal Hardware User’s Manual (V117)
4-4 Sys
tem
Menu
Det
ails
4
4-
4-5 N
J/NX/N
Y
T
ro
ubleshooter
(Pr
oject System Men
u)
When Connected to an NJ-series CPU Unit
System configuration element
Troubleshooter functions
Displaying
errors
Clearing
errors
Displaying
error logs
Clearing error
logs
CPU Rack
CPU Unit
Applicable
CJ-series Units
Applicable
Partially applicable
*1
*1. You cannot display or delete events in the error history (upper four digits of event code are 0000 hex) in a
CJ-series Special Unit mounted on an NJ-series CPU Unit.
EtherCAT Slaves (Sysmac devices)
Applicable
Applicable
*2
*2. Supported in runtime version 1.03 or higher.
Applicable
*2 *3
*3. Event logs for individual units cannot be cleared.
EtherCAT Slave Ter-
minals
EtherCAT Cou-
pler Units
Applicable
Applicable
*2
Applicable
*2 *3
NX Units
Partially appli-
cable
*4
*4. Events are not displayed for some NX Units. If an error occurs in an NX Unit that does not display events, an
NX Unit Minor Fault event will occur in the EtherCAT Coupler Unit and the unit number of the NX Unit in which
the error occurred will be given in the attached information.
Applicable
*5
*6
*5. Errors that occur on a specific NX Unit cannot be cleared separately.
*6. It might be necessary to reset errors in Safety Control Units with a safety program. Refer to the
NX-series Safe-
ty Control Unit User’s Manual
(Cat. No. Z930) for details on resetting errors in Safety Control Units.
Applicable
*2
Applicable
*2 *3
When Connected to an NY-series CPU Unit
System configuration element
Troubleshooter functions
Displaying
errors
Clearing
errors
Displaying
error logs
Clearing error
logs
CPU Unit
Applicable
EtherCAT Slaves (Sysmac devices)
Applicable
Applicable
*1
*1. Supported in runtime version 1.06 or higher.
Applicable
*1 *2
*2. Event logs for individual units cannot be cleared.
EtherCAT Slave Ter-
minals
EtherCAT Cou-
pler Units
Applicable
Applicable
*1
Applicable
*1 *2
NX Units
Partially appli-
cable
*3
*3. Events are not displayed for some NX Units. If an error occurs in an NX Unit that does not display events, an
NX Unit Minor Fault event will occur in the EtherCAT Coupler Unit and the unit number of the NX Unit in which
the error occurred will be given in the attached information.
Applicable
*4
*5
*4. Errors that occur on a specific NX Unit cannot be cleared separately.
*5. It might be necessary to reset errors in Safety Control Units with a safety program. Refer to the
NX-series Safe-
ty Control Unit User’s Manual
(Cat. No. Z930) for details on resetting errors in Safety Control Units.
Applicable
*1
Applicable
*1 *2
Summary of Contents for OMRON NA Series
Page 8: ...Sections in this Manual 6 NA series Programmable Terminal Hardware User s Manual V117...
Page 12: ...CONTENTS 10 NA series Programmable Terminal Hardware User s Manual V117...
Page 34: ...Revision History 32 NA series Programmable Terminal Hardware User s Manual V117...
Page 82: ...3 Installation and Wiring 3 22 NA series Programmable Terminal Hardware User s Manual V117...
Page 164: ...5 Troubleshooting 5 18 NA series Programmable Terminal Hardware User s Manual V117...
Page 179: ...I 1 I NA series Programmable Terminal Hardware User s Manual V117 Index...
Page 181: ......