Synway Information Engineering Co., Ltd
SMG-D Series Analog Gateway User Manual (Version 2.0.0)
Page 36
FWD Type
Forward conditions for the FXS port to forward incoming IP calls. The optional
values are:
Option
Description
Unconditional
The FXS port will forward all incoming IP calls to the preset
FWD Num
immediately when it receives them.
Busy
The FXS port will forward incoming IP calls to the preset
FWD
Num
if it is busy upon receiving them.
No Reply
The FXS port will forward incoming IP calls to the preset
FWD
Num
if the corresponding station does not answer them in a
designated time period (i.e.
Time for No Reply Forward
). Only
when this forward condition is selected does the configuration
item
Time for No Reply Forward
become valid.
This item is valid only when
Call Forward
is set to
Enable
.
FWD Num
The number to which the incoming IP call is forwarded. If the
Call Forward
feature
is enabled, this item can not be left empty.
Color Ring
Sets whether to enable the color ring feature or not, with the default setting of being
disabled
.
Note:
Only when there are available color rings will this item appear.
Color Ring Index
The index of the color ring which will be quoted by the current FXS port.
Talkback
With this feature enabled and a number bound, the port can talkback to its bound
number. That is, they can start a call with each other as soon as picking up the
phone. The default setting is
disabled
.
Note: This feature is only used in the case of channel registration.
Bound Number
Sets the bound number for talkback.
Ringing Parameter
Set the ringing parameters of the FXS module. The default value is
RING_ABS120V_DEF.
Note: It is not necessary to change this value under normal circumstances. For
modification, please contact our technical support.
Feed
Voltage
Parameter
Set the feed voltage parameters of the FXS module. The default value is
DCFEED_48V_21MA_DEF.
Note: It is not necessary to change this value under normal circumstances. For
modification, please contact our technical support.
Impedance
Parameter
Set the impedance parameter of the FXS module. The default value is
ZSYN_200_680_100_30_0.
Note: It is not necessary to change this value under normal circumstances. For
modification, please contact our technical support.
After configuration, click
Modify
to save the settings into the gateway, click
Reset
to restore the
configurations, or click
Cancel
to cancel the settings.
Or you can click
Batch
to modify several pieces of FXS settings at the same time. The
configuration items on the FXS batch modification interface are the same as those on the FXS
modification interface.
Some configuration items on this interface are the same as those on the
FXS Modification
Interface
. The others are described in the table below.