自動化產品
/Automation Products
–
70SB Laser Marking Machine Assembly Manual(Discontinued)
Troubleshooting Q&A
–
41
a.
a.
b.
a.
b.
c.
a.
b.
Galvanometer is noisy
-
Wire
contact
failure
1. Check whether the wire
from the galvanometer to
the controller is properly
connected, galvanometer X
to Axis-1, galvanometer Y to
Axis-2
2. Wires are properly
attached.
After power on, the
limit Pin of the
galvanometer motor
reaches the positive /
negative limit.
Paramete
r error
Motor
hardware
failure
Check whether the
resonance suppression
coefficient or torque
filter coefficient of the
galvanometer is correct
(the controller has no
such function)
Turn the motor with
your hand to check
whether the motor
rotates smoothly and
reassemble it
Disassemble the motor,
check whether the disc
or axle sleeve is loose,
and reassemble it
11.2
Production correction
Problem
Fig
ure
Possible cause
Elimination
methods
The axial operation is not
smooth after resonance
suppression.
-
1. Loosening of axle
sleeves
2. Assembly
problem
Replace axis
Reassemble