technical reference
3
9
Synrad
Pulstar p100
operator’s manual
Controlling laser power
Table 3-2
Pulse frequency/duty cycle range
Input Frequency
Duty Cycle Range
< 50 kHz
0% – 37.5%
50 – 75 kHz
0% – 31.5%
> 75 kHz
0% –25.0%
Pulstar’s
User I/O
PWM input consists of a high-speed optoisolator LED with a forward voltage drop (Vf)
of 1.5 VDC. The PWM input frequency can range from a single-shot up to 100 kHz. Table 3-3 provides
minimum, maximum, and nominal PWM signal specifications.
Table 3-3
PWM Command signal specifications
Laser State
Minimum
Nominal
Maximum
Laser Off
0.0 VDC
0.0 VDC
+0.8 VDC
Laser On
+3.5 VDC (3 mA)
+5.0 VDC
+6.7 VDC (10 mA), continuous
Frequency Range
Single-shot
— —
100 kHz
Duty Cycle
0%
— —
37.5%
1
1 Varies by pulse frequency. Refer to Table 3-2 for details.
Summary of Contents for Pulstar P100 Series
Page 2: ......
Page 4: ......
Page 12: ...x Synrad Pulstar p100 operator s manual This page intentionally left blank...
Page 48: ...operation 210 Synrad Pulstar p100 operator s manual This page intentionally left blank...
Page 110: ...index i8 Synrad Pulstar p100 operator s manual This page intentionally left blank...