getting started
1
7
Synrad
Pulstar p100
operator’s manual
Mounting
Important Note:
Verify the correct fastener length for your mounting application. When fastening
the Pulstar p100 to your mounting surface,
be sure the fasteners do not extend
further than 11.0 mm (0.433”) into the laser’s base plate
.
3
Insert three M6 × 1 ISO or 1/4–20 UNC fasteners through the mounting surface into the corre-
sponding threaded holes in the p100 base plate. Turn the screws by hand until the threads engage.
4
Evenly tighten all three fasteners to a maximum torque of 6.1 N m (54 in lb).
Mount from above
(using optional mounting feet)
To fasten the OEM p100 laser onto a mounting surface, you will need to purchase and install the optional
p100 mounting kit, SYNRAD P/N 250-20440-01 (available separately from the factory).
Attach the optional mounting feet
To attach the optional mounting feet to the OEM p100 laser, perform the following steps:
1
Carefully place the p100 laser upside down on a padded work surface with the beam exit facing
towards the left.
2
Locate the mounting feet in the optional mounting kit and orient the feet as shown in Figure 1-3.
The arrow machined on the front foot should be visible and point towards the front of the laser.
Figure 1-3
Attach optional p100 mounting feet
3
Locate the six flathead screws in the optional p100 mounting kit and refer to Figure 1-3 or Figure
4-20 (the p100 O&M drawing, sheet 2 of 2) for ISO and UNC fastener locations on the base plate.
Front Holes - SAE Fasteners - 1/4–20 × 5/8” UNC Black Oxide Finish
Rear Holes - ISO Fasteners - M6 × 1 × 12 mm Stainless Steel Finish
Summary of Contents for Pulstar P100 Series
Page 2: ......
Page 4: ......
Page 12: ...x Synrad Pulstar p100 operator s manual This page intentionally left blank...
Page 48: ...operation 210 Synrad Pulstar p100 operator s manual This page intentionally left blank...
Page 110: ...index i8 Synrad Pulstar p100 operator s manual This page intentionally left blank...