getting started
1
14
Synrad
Pulstar p100
operator’s manual
Connecting
Note:
Because AC input connections and requirements vary from facility to facility, customers
must provide the AC power cable or wiring. AC input connections to the PS-48 DC power
supply are made using a three-position terminal strip with M4 screw terminals on 13.0 mm
centers.
5
Connect the ground (earth) wire, typically green, to the input terminal labeled with the
ground symbol.
6
Connect the neutral AC wire, typically white or blue, to the input terminal labeled “AC/N”.
7
Connect the hot AC wire, typically black or brown, to the AC input terminal labeled “AC/L”.
Control connections
All control connections to Pulstar p100 lasers are made through the 15-pin
User I/O
connector on
the rear panel. The
User I/O
port receives power commands from SYNRAD’s UC-2000 Universal Laser
Controller, or FH Flyer marking head, and also serves as the connection point for auxiliary signals between
the laser and any parts handling, automation, or monitoring equipment.
Warning
serious
personal
injury
Always use shielded cable when connecting your pulse signal source
to
PWM Input / PWM Return
inputs. In electrically-noisy environ-
ments, long lengths of unshielded wire act like an antenna and may
generate enough voltage to trigger uncommanded lasing.
Quick Start Plug
Warning
serious
personal
injury
The use of the
Quick Start Plug
bypasses the laser’s safety interlock
function, potentially exposing personnel in the area to
invisible
infrared laser radiation.
Because this plug jumpers
Remote Interlock
and
Shutter Open
Request
signals, the laser will fire immediately on application of
a PWM Command signal. Your integrated control system should
provide interlock and shutter signals directly to the DB-15
User I/O
connector only after safe operating conditions are established.
The
Quick Start Plug
is intended only for initial testing and trouble-
shooting by qualified personnel. In normal operation, the laser’s
Remote Interlock
input should be connected to the machine’s safety
interlock circuitry.
Summary of Contents for Pulstar P100 Series
Page 2: ......
Page 4: ......
Page 12: ...x Synrad Pulstar p100 operator s manual This page intentionally left blank...
Page 48: ...operation 210 Synrad Pulstar p100 operator s manual This page intentionally left blank...
Page 110: ...index i8 Synrad Pulstar p100 operator s manual This page intentionally left blank...