Section II
General Product Information
006-0006715 10/31/18
Rev J
21 of 44
MPS-MPPS-4000 Guide
www.synqor.com
MPS Droop Characteristics - All Ouput Voltages
The MPS output voltage is semi-regulated. As the output current increases, the output
voltage will decrease. Typically, the output voltage will decrease by 10% at full load.
Note that the full rated output power of 4000 W can be derived from the AC INPUT having a
voltage within this uncommon range for up to 15 seconds before the MPS will shutdown its
output. Also note that the MPS can drive at full rated power for a 2 second interval even if
the AC INPUT voltage drops below 100 V
rmsL-L
.
27.5
28.0
28.5
29.0
29.5
30.0
30.5
0
20
40
60
80
100
120
140
160
180
Ou
tpu
t V
ol
ta
ge
(V
)
115Vrms L-L:
Continuous
Operation
Region
Maximum Transient
Duty and On-Time
208Vrms L-L:
Transient
Operation
Regions
2s 20%
120s 50% 15s 20%
Output Load (A)
Figure 6: 28Vout Droop Characteristics
Output Load (A)
Figure 7 : 30Vout Droop Characteristics
29.0
29.5
30.0
30.5
31.0
31.5
32.0
32.5
33.0
0
20
40
60
80
100
120
140
160
Ou
tpu
t V
ol
ta
ge
(V
)
115Vrms L-L:
Continuous
Operation
Region
Maximum Transient
Duty and On-Time
208Vrms L-L:
Transient
Operation
Regions
2s 20%
120s 50% 15s 20%
Output Load (A)
Figure 8: 48Vout Droop Characteristics
48.0
48.5
49.0
49.5
50.0
50.5
51.0
51.5
52.0
0
10
20
30
40
50
60
70
80
90
100
Ou
tpu
t V
ol
ta
ge
(V
)
115Vrms L-L:
Continuous
Operation
Region
Maximum Transient
Duty and On-Time
208Vrms L-L:
Transient
Operation
Regions
2s 20%
120s 50% 15s 20%