49
• Visually check the battery for leakage.
Clean all of the electrical contacts inside the terminal with a contact cleaner.
Checking Backup battery:
Making sure that the backup battery is in good condition, according to the following steps:
1. Collect and clear all the data stored in the terminal.
2. Open the terminal.
3. Remove jumper JP7.
4. Check the voltage of the memory back-up battery and make sure it is between 2.8V and 3.1V.
5. Replace jumper JP7.