12713140-003-2 Revision E.01 – January 2007
SSU-2000e Technical Reference 123
Chapter 2 TL1 Reference
Set Clock Parameters
Set Clock Parameters
This command sets the warmup time and tau values for the specified Clock module.
Syntax
SET-PRMTR-CLK:[tid]:[aid]:ctag::[warmup],[mintau],[maxtau];
Empty fields leave parameters unchanged.
Related Commands
Parameter
Format
Description
aid
S1A1
Sets the parameters for the Clock module in slot 1.
S1A12
Sets the parameters for the Clock module in slot 12.
null
Sets the parameters for both Clock modules.
warmup
Sets the warmup time constant; set to 1200 seconds
mintau
Sets the starting time constant for the specified Clock
module.
maxtau
Sets the final time constant value for the specified Clock
module
ST2E tau range = [300–10 000]
ST3E tau range = [150–1200]
TYPEI tau range = [150–1200]