BackupStore 5000
Routine Maintenance
3 Guide to the On-Site Routine Maintenance of the
Device
Issue 01 (2010-03-26)
Symantec Corporation
3-5
Location
Indicator
Color
Status
Description
module
indicator
Green
Blinking
The AC power is
normal but the device is
not powered on.
Orange
On
An alarm is generated
on the power module.
-
Off
The power module is
not powered on.
Mainboard
Fan running/alarm
indicator
Green
On
The fan is running
properly.
Red
On
An alarm is generated
on the fan.
Rear panel
Link indicator of the
management network
port
Green
On
The link of the
management network
port is normal.
-
Off
No link.
Active indicator of the
management network
port
Yellow
Blinking
Data is being
transmitted.
-
Off
No data is being
transmitted.
Link indicator of the
service network port
Green
On
The speed of the data
transmission between
the NetBackup 5000
and the AS is 1000
Mbit/s.
Orange
On
The speed of the data
transmission between
the NetBackup 5000
and the AS is 100
Mbit/s.
-
Off
The speed of the data
transmission between
the NetBackup 5000
and the AS is 10 Mbit/s
or no link.
Active indicator of the
service network port
Yellow
Blinking
Data is being
transmitted.
-
Off
No data is being
transmitted.
a: A location command is sent from the management system.