EQUIPMENT DET
AILS
94
TROUBLE SHOOTING GUIDE
(COMBI GAS HEATER)
FAULT
CODE
CAUSE
REMEDY
# 17
Summer mode with empty water container
Switch heater off and allow to cool. Fill boiler
with water
# 18
Warm air temperature exceeded:
Not all warm air ducts are connected
Check whether the 4 warm air ducts are
connected
Warm air oulets blocked
Check the individual outlet openings
Circulated air intake blocked
Remove the circulated air intake blockage
# 21
Room temperature sensor or cable faulty
Inspect the room temperature sensor cable,
replace if faulty
Check the resisitance of the room temperature
sensor.
15°C - 16.2 kOhm / 20°C - 12,6 kOhm / 25°C
- 10.0 kOhm
Replace room temperature sensor if faulty
# 24
Risk of low voltage. Battery voltage is too low
< 10.4V
Charge battery
# 29
Frost Control heating element has a short circuit Disconnect heating element plug from
electronic control unit. Replace heating element
# 42
Open window above cowl (window switch)
Clode window
# 43
Overvoltage > 16.4V
Check battery voltage / voltage sources such
as the charger
# 44
Low voltage. Battery voltage is too low <10.0V
Charge battery. If necessary replace old battery
# 45
No 230 V operating voltage
Restore 230 V operating voltage
230 V fuse defective
Replace 230 V fuse (see Combi operating
instructions)
Overheating protection has been triggered
Reset overheating protection (see Combi
operating instructions)
# 112
# 121
# 122
# 202
# 211
# 212
Gas cylinder empty
Replacing a gas cylinder
Gas cylinder or quick-acting valve in the gas
supply line closed
Check gas supply and open valves
Gas pressure regulation system iced up
Use regulator heater (EisEx)
Butane content in the gas cylinder too high
Use propane. Butane is unsuitable for heating,
particularly at temperatures lower than 10 °C.
Combustion air infeed or exhaust outlet is
sealed
Inspect openings for obstructions (slush, ice,
leaves, etc.) and remove any obstructions
Gas pressure regulation system faulty
Inspect / replace gas pressure regulation
system
# 255
Heater has no 12 V power supply
Ensure 12 V power supply
No connection between heater and control
panel
Make connection between heater and control
panel
# 301
# 417
Overvoltage > 16.4 V
Check battery voltage / voltage sources such
as the charger
# 303
# 411
Risk of low voltage. Battery voltage is too low
< 10.4 V
Charge battery
# 401
Summer mode with empty water container
Switch heater off and allow to cool. Fill boiler
with water
Summary of Contents for Select 122
Page 29: ...E N R OU T E 25 EN ROUTE Fix Go tyre repair kit 26 Cruise Control 28 Parking Sensors 28...
Page 38: ...A RRIVA L AT SIT E 35 ARRIVAL AT SITE Positioning the Motorhome 36...
Page 50: ...CO N NE CT ING SE R VICE S 47 Typical gas schematic drawing with combi boiler GAS SCHEMATIC...
Page 126: ...MO TOR HOME CA R E 125 BED MAKE UP Bed make up in Select 184 rear bed...
Page 134: ...134 Van Conversion Jacking Point T E CHN ICA L IN FO RMATIO N JACKING POINTS...