1. INTRODUCTION: 

 

The Live T26 is a high power smoke generator. Due to the very precise output control and 
the integrated fan outlet control, the machine can be used for many purposes.  
 

 

Very high output – 1,800 m

3

 / minute at full power. 

 

Continous operation at 50% output or below. 

 

Precise output control 1 – 100%, adjustable in 99 steps.  

 

Cast aluminium heat exhanger with dual stainless steel vaporizer coils.  

 

Built with the use of industrial quality components. 

 

Full R.I.S.C. microprocessor control. Software upgrade-able. 

 
We hope that you will be fully satisfied with the performance of Swefog Live T26. To keep 
your machine functioning like new for its entire life, it is important to follow the instructions 
in this manual and to have regular maintenance of the machine. 
 
For the best results, use only original waterbased Swefog original smoke or haze fluid in the 
machine. 

Use of any other fluid will void the warranty. 

 

 

1.1 A few words about smoke fluid – What is a “quality” fluid? 

 
Most waterbased smoke or haze fluids contains glycols. The glycols in the mixture creates 
the white particles that we recognizes as smoke or haze. Mainly, there are two very important 
things to remember about fluids and smoke machines:  
1: The water must be de-ionized. If the water contains minerals like calcium, salt etc; the heat 
exchanger´s pipes will first be coated (causes poor output), and finally it will clogg the pipes 
completely, and your machine is damaged. The pipes cannot be cleaned. 
2: The glycol used in the mixture has to be very clean. If not, it may clogg the heat 
exchanger, and most important of all, if the glycol is not 100% pure, it may be hazardous for 
health, as it will contain a few promilles of unknown substances which may be dangerous for 
health when heated. 
 
And there is one very important thing to remember about fluids and health safety: 
There are many low-cost fluids available, manufactured from water and chemicals with 
unknown purity. The Live T26 will probably work with most of them, but always remember: 
You will always get what you paid for, use original fluid. Why? The T26 is a high 
performance machine, and it is developed with Swefog fluids. If other fluids are used, 
remember, these fluids are not tested & approved by the manufacturer. Other fluids can be 
mixed for a different vaporize (heater) temperature or contain other chemicals and / or a 
different balance between water and glycols in the mixture. There might be problems with 
bad (“wet”) or even toxic smoke, which can cause serious personal injury. A clogged heater 
block is able to replace. Personal injurys are worse. Always remember, you are responsible 
for the safety of the smoke appliance. The manufacturer cannot be held responsible if the 
wrong type of fluid is used. 
Non-toxic smoke and the longest lifetime of your machine is achieved with the original fluids 
your machine once was developed for. And by using Swefog original fluids, you´ll be 100% 
sure the smoke produced by your machine is clean. 
Swefog smoke & haze fluids are based on pure, de-ionized Swedish water which is de-
mineralized in an industrial laboratory, and guaranteed free from minerals. It contains glycol 
of pharama (medical) quality only – the finest and most pure glycols available. The fluid is 
mixed and bottled in our factory, which guarantees full production quality control, and a 
clean fluid of the highest quality. 
 
We strongly recommend that you use Swefog original smoke fluid in your machine. Swefog 
fluids are not more expensive than any other high quality smoke fluid. 

Summary of Contents for 40 201-240

Page 1: ...LIVE T26 IVE T26 X POWER HD SMOKE PROCESSOR X POWER HD SMOKE PROCESSOR OWNER S MANUAL Item no 40 201 240 Live T26 240V 50Hz SWEFOG O M PEN INDS...

Page 2: ...lle Warnungen sorgf ltig bevor Sie das Ger t zusammenbauen installieren und benutzen IMPORTANTE Por favor lea todas las precaucionas y las advertencias antes de ensamblar montar y operar este equipo I...

Page 3: ...Mains cable 11 7 2 DMX connection 11 7 3 DIN Remote 0 10V analogue connection 12 7 4 FAN connection 12 8 OPERATION 13 8 1 Control panel display 13 8 2 Operation mode 14 8 2 1 DMX mode 14 8 2 2 MANUAL...

Page 4: ...Not heeding these messages could result in serious personal injury The owner s manual contains important safety precautions and information on how to use your machine Always read the owner s manual be...

Page 5: ...will contain a few promilles of unknown substances which may be dangerous for health when heated And there is one very important thing to remember about fluids and health safety There are many low cos...

Page 6: ...electronic module controls the temperature in the heater block and the pump speed When smoke is produced the pump starts to pump smoke fluid into the heater Due to the very high temperature in the he...

Page 7: ...oo low for the selected output the EPR will automatically reduce the pump speed This is a fully automatic system controlled by the processor and cannot and should not be disabled or modified by the us...

Page 8: ...head Use responsible concentrations of fog to create atmospheric effects NOT for residential use Operate in room temperature only NEVER cover vents or air inlets on the machine housing Service interna...

Page 9: ...with the machine Ensure an airtight connection RISK OF FIRE OR EXPLOSION NEVER use any kind of flammable liquid in the machine OUTPUT NOZZLE BECOMES EXTREMELY HOT Keep hands off 3 Place the canister...

Page 10: ...l Below this point the pumps are unable to run The machine can produce smoke continous without interrups for re heating at output levels below 50 If the machine is to be used for continous operation m...

Page 11: ...mains plug approved for min 16 Amps RISK OF ELECTRIC SHOCK Refer to qualified personnell if the mains cable must be modified or replaced NEVER use a damaged cable 7 2 DMX Connection 1 2 3 4 5 1 5 3 2...

Page 12: ...Pin 5 12V out used with Swefog remote control only NOT for use with a light desk or for any other purpose Do NOT link or short circuit any pins It may damage the machine s electronics If an external v...

Page 13: ...by indicator illuminates GREEN The T26 will require approximately 8 minutes to heat to a minimum operational temperature and approximately 10 minutes to heat to its highest temperature STANDBY INDICAT...

Page 14: ...or s memory when the machine is switched off and or mains voltage is disconnected This address is default next time the machine is switched on In an application where the machine is used with the same...

Page 15: ...g Live T26 or other DMX fixture IN DMX OUT Swefog Live T26 or other DMX fixture IN DMX OUT 1 2 n 8 2 2 Manual mode stand alone Select manual mode if you wish to operate the machine from its keypad onl...

Page 16: ...between operate and delay time Press MENU to exit Set operate time 00 00 min sec Set delay time 00 00 min sec 2 Set fog output level P and fan speed Fan Use the buttons to set an output level from 0 t...

Page 17: ...ctrical parts are OFF The machine uses a power save circuit which senses the OK button only for switching on 8 3 External fan control output Connect a 1 phase 230V fan to the IEC fan outlet Maximum fa...

Page 18: ...not facing backwards and or the magnetic floatchamber is inside the canister NOTE Iron filings will get caught to the magnetic floatchamber and corrode which will result as small brown dots Clean the...

Page 19: ...t kit Assemble and install the kit according to the instructions provided with the kit Always use the safety wire provided Wrong installation of the flying bracket kit may cause serious personal injur...

Page 20: ...ontains basic trobleshooting only For serious problems with your machine contact your Swefog dealer 9 1 Software The Live T26 uses a powerful microprocessor for control of all functions The microproce...

Page 21: ...This will avoid crack noise and reduce high peak loads on internal compenents THE EXTERNAL FAN DOES NOT WORK Q Check the fan fuse Is the fuse OK YES Check the fan and the connection See chapter 6 for...

Page 22: ...Please note there might be other error messages displayed depending on updated software and technical changes improvments Check with your dealer or at www swefog com for an updated manual and service...

Page 23: ...wefog haze fluid It is the owner s responsibility to furnish receipts or invoices for verification of purchase date and dealer or distributor If purchase date cannot be provided date of manufacture wi...