16
8.2.3. Timer mode:
Select timer mode to produce fog with fixed time intervals. The T26 uses the microprocessor
to control operate / delay time, which makes the timer very precise.
Time:
00:
00 smoke
>P:
0% FAN 0%
1. INTRODUCTION:
The machine is using the microprocessor to control the timing process, which makes smoke
& delay times 100% precise.
NOTE: Do not program short operate time intervals (below 7 seconds) if you have selected a
high fog output. The pump soft start system will prevent the pumps to run at full speed the
first seconds.
2. PROGRAMMING THE TIMER:
1.
Press MENU to set operate and delay time. Use the
▲
/
▼
buttons to set time in seconds. Use
the
◄
/
►
buttons to change between operate and delay time. Press MENU to exit.
Set operate time
00:
00 (min:
sec)
◄
/
►
Set delay time
00:
00 (min:
sec)
2.
Set fog output level (P) and fan speed (Fan): Use the
▲
/
▼
buttons to set an output level
from 0 to 100%. Press and hold for faster count. Use the
◄
/
►
buttons to change between
smoke output and fan speed. An arrow indicates whether the smoke output ( >P ) or the fan
speed ( >Fan ) is set.
3. ACTIVATING THE TIMER:
1.
Press
OK
button to start the timer. The YELLOW “Timer” indicator illuminates. The display
indicates remaining time (operate / delay). The RED “smoke on” indicator illuminates when
machine is operating. The indicator is off at delay status.
Time:
00:
24 smoke
>P:
75% FAN 100%
NOTE: The soft start system always starts the machine at 20% fog output. After a few
seconds the machine will produce fog at selected level.
2.
Press
OK