18
8.4 Mode Memo System (MMS):
At power on, the machine will automatically start in the same operation mode as used last
time. In DMX mode, it also remember the last programmed DMX address. Read more, see
chapter 2, “DMX mode”.
The MMS feature is a handy function for permanent installations, touring or any other
application where the machine is always used with the same operation mode.
8.5 Low Fluid Sensing – LFS
Fluid level low
Pumps disabled
The T26 is equipped with a wireless low fluid level sensing system, which will prevent the
pumps from running dry. The LFS system uses a magnetic switch underneath the fluid
canister, and a magnetic floatchamber inside the canister. When the fluid level is low (approx.
0,5 L), the pumps are disabled, and a message appears in the display.
The system will not work if the fluid cap is not facing backwards, and / or the magnetic
floatchamber is inside the canister.
NOTE: Iron filings will get caught to the magnetic floatchamber and corrode, which will
result as small, brown dots. Clean the floatchamber every time the fluid is changed or
replaced. Magnetic metal particles can be removed with a short burst with compressed air, or
a magnet.
8.6 Mechanical overheat protection:
The T26 uses three mechanical overheat protection switches: One for each pump, and one 16
Amp. thermostat for the heater block. All will automatically reset after an activation.
8.7 Ducting system:
If the machine is to be used with a fog distribution system, it should be placed so that the fog
is discharged into the distribution system´s inlet or as directed by the distribution systems
instructions. Always use the Swefog ducting system adaptor (optional). Do NOT slip the
tubing over the end of the machine´s output collar.
CAUTION! Using a ducting system may result in smoke fluid residues, which may cause
slippery floors.
!
CAUTION !