12
7.3 DIN Remote / 0-10V analogue connector:
DIN 41 524 pinout:
1
2
3
4
5
1
3
2
4
5
Female connector on machine
Male plug from Swefog analogue remote controller or a 0-10V
lightdesk.
Use a 5-pin male DIN plug for connection of an analogue remote control.
Pin 1 = Smoke density (not used on T26).
Pin 2 = Ground
Pin 3 = Fan speed
Pin 4 = Smoke output
Pin 5 = +12V out (used with Swefog remote control only, NOT for use with a light desk or
for any other purpose).
Do NOT link or short circuit any pins! It may damage the machine´s electronics.
If an external voltage source (e.g. a lightdesk) is used, NEVER 12V output voltage!
See chapter 6:4 (Operation: Remote / 0-10V mode) for further information.
7.4 FAN Connector:
Live + Neutral
Earth
Use a cable with IEC male connector for power supply to an external fan.
The connected fan must be earthed.
NEVER use a 2-pin IEC connector without earth.
WARNING