AMU Powercon
Default Values
10. Default Values
Operation:
Sensors
Filter Time Const.:...................................................................... 10 s
Hold after Cal.:......................................................................... 300 s
Relay Contacts
Alarm Relay .................................................. same as in Installation
Relay 1/2 ...................................................... same as in Installation
Input.............................................................. same as in Installation
Logger
Logger Interval:..................................................................... 30 min
Clear Logger:................................................................................no
Installation:
Sensors
Flow: ........................................................................................ None
Sensor Parameters; Cell Constant ...............................0.0415 cm
-1
Sensor Parameters; Temp. corr. ...........................................0.00 °C
Sensor Parameters; Cable length............................................0.0 m
Sensor Parameters; Meas. unit .............................................µS/cm
Temp. Compensation; Comp. ...................................................none
Quality Assurance; Level ......................................................... 0: Off
Signal Output 1
Parameter: .................................................................... Conductivity
Current loop:......................................................................4–20 mA
Function:.................................................................................. linear
Scaling: Range low:........................................................... 0.000 µS
Scaling: Range high:................................................................ 1 mS
Signal Output 2
Parameter: ....................................................................Temperature
Current loop:......................................................................4–20 mA
Function:.................................................................................. linear
Scaling: Range low:...................................................................0 °C
Scaling: Range high:................................................................50 °C
Alarm Relay
Alarm Conductivity:
Alarm high:........................................................................... 300 mS
Alarm low:.......................................................................... 0.000 µS
Hysteresis: ........................................................................... 1.00 µS
Delay:........................................................................................... 5 s
Sample Flow:
Flow Alarm .................................................................................. yes
Alarm high:.............................................................................. 20 l/h
Alarm low:................................................................................. 5 l/h
Sample Temp:
Alarm High:............................................................................160 °C
Alarm Low:.................................................................................0 °C