![Svantek SVAN 948 User Manual Download Page 26](http://html1.mh-extra.com/html/svantek/svan-948/svan-948_user-manual_1409249026.webp)
SVAN 948 USER MANUAL
3 - 7
v
DISPLAY
(one of the main lists available after pressing the
<MENU>
push-button)
DISPLAY MODES
(sub-list); it enables the user to activate (
[
√
√√
√
]
) or switch off (
[ ]
) the available
modes of result’s presentation
§
SPECTRUM
(position); available values:
[
√
√√
√
]
or
[ ]
; this position is not active in the
SLM
or
VLM
mode
§
3 PROFILES
(position); available values:
[
√
√√
√
]
or
[ ]
§
STATISTICS:
(position); available values:
[
√
√√
√
]
or
[ ]
§
PLOT:
(position); available values:
[
√
√√
√
]
or
[ ]
DISPLAY SETUP
(sub-list)
§
CHANNEL x
•
DISPLAY SCALE:
(sub-list)
o
SCALE
: (position); available values of the scale of graphical modes of the result’s
presentation:
LIN
(linear),
LOG
(logarithmic) - in the case of vibration measurements and
LOG
(logarithmic) - in the case of sound measurements
o
DYNAMIC
: (position); available values of the dynamics of graphical modes of the
result’s presentation:
80dB, 40dB, 20dB, 10dB
o
X-ZOOM
: (position); it informs the user about the multiplier for the horizontal axis
of the graphical modes of the result’s presentation):
1x
•
TOTAL VALUES
o
TOTAL 1:
(sub-list) enables to select the weighted filter to be used for the
calculation of the
TOTAL
value in the first profile
FILTER:
(position); available values of the weighted filters:
•
in the case of sound measurements:
A
,
SUSR1
,
SUSR2
,
SUSR3
or any
other sent to the unit by means of the interface
•
in the case of vibration measurements:
HP, VUSR1, VUSR2, VUSR3
or
any other sent to the unit by means of the interface
TYPE:
(position available only for vibration measurements); available values
if
VUSR1, VUSR2
or
VUSR3
was selected in the previous position:
ACC,
VEL
and
DIL
; if the
HP
filter was selected this position is not displayed
CAL. F.:
(position available only for vibration measurements); accessible if
VUSR1, VUSR2
or
VUSR3
was selected in the
FILTER
position; if the
HP
filter was selected (the filter which was set in the 1
st
channel) this position is
not displayed; available values from
-60.0dB
to
60.0dB
with
0.1dB
or
1 dB
step
o
TOTAL 2:
(sub-list) enables one to select the weighted filter to be used for the
calculation of the
TOTAL
value in the second profile
FILTER:
(position); available values of the weighted filters:
•
in the case of sound measurements
: C, SUSR1, SUSR2, SUSR3
or any
other sent to the unit by means of the interface
•
in the case of vibration measurements:
CH, VUSR1, VUSR2, VUSR3
or
any other sent to the unit by means of the interface
TYPE:
(position available only for vibration measurements); available values
if
VUSR1, VUSR2
or
VUSR3
was selected in the previous position:
ACC,
VEL
and
DIL;
if the
CH
filter was selected (the filter which was set in the 2
nd
channel) this position is not displayed
CAL. F.:
(position available only for vibration measurements); accessible if
VUSR1, VUSR2
or
VUSR3
was selected in the
FILTER
position; if the
CH
filter was selected (the filter which was set in the 2
nd
channel) this position is
not displayed; available values from
-60.0dB
to
60.0dB
with
0.1dB
or
1 dB
step
Summary of Contents for SVAN 948
Page 1: ...SVAN 948 SOUND AND VIBRATION DATA LOGGER USER S MANUAL SVANTEK Sp z o o WARSAW June 2004...
Page 19: ...SVAN 948 USER MANUAL 2 6 The view of the rear panel of the SVAN 948 instrument in 1 1 scale...
Page 25: ...SVAN 948 USER MANUAL 3 6 Control diagram of the INPUT list...
Page 28: ...SVAN 948 USER MANUAL 3 9 Control diagram of the DISPLAY list...
Page 30: ...SVAN 948 USER MANUAL 3 11 Control diagram of the FILE list...
Page 32: ...SVAN 948 USER MANUAL 3 13 Control diagram of the AUX FUNCTION list...
Page 36: ...SVAN 948 USER MANUAL 3 17...
Page 37: ...SVAN 948 USER MANUAL 3 18 Control diagram of the SETUP list...