SVAN 948 USER MANUAL
3 - 5
BUFFERS SETUP:
(sub-list) available types of measurement results which has to be saved in the
instrument’s buffer from the channels:
o
None
,
PEAK
,
P–P
,
MAX
,
RMS
- in the case of vibration measurements and
o
None
,
PEAK
,
MAX
,
MIN
,
RMS
- in the case of sound measurements
o
VECTOR:
available value of VECTOR which has to be saved in the instrument’s buffer
1/1 OCTAVE SETUP
or
1/3 OCTAVE SETUP
(sub-list)
§
CHANNEL x:
o
SPECTRUM
(sub-list); this sub-list is not available in the case of the
SLM
or
VLM
; it
appears on the display in the case of
1/1 OCTAVE
or
1/3 OCTAVE
analyser
•
FILTER
(position); available types of the digital weighting filter used during
1/1 OCTAVE
or
1/3 OCTAVE
analysis in the case of sound measurements:
HP
,
LIN
,
A
,
C
•
BUFFER
(position); available types of measurement results which has to be
saved in the instrument’s buffer during
1/1 OCTAVE
or
1/3 OCTAVE
analysis:
o
None, RMS
- in the case of vibration measurements
o
None, RMS, LEQ
- in the case of sound measurements
TRIGGER SETUP
(sub-list)
§
TRIGGER
(position); available values:
Off
,
SLOPE +
,
SLOPE -
,
LEVEL +
,
LEVEL -
,
BUFFER
§
SOURCE:
(position); it informs the user about the source of the triggering signal:
§
SOURCE:
(position); it informs the user about the source of the triggering signal:
o
VECT, RMS
,
125Hz
,
250Hz
,
500Hz
,
...
,
16kHz
- in the case of vibration measurements,
BUFFER
selected in the
TRIGGER
position and
1/1 OCTAVE
function;
VECTRMS
,
125Hz
,
160Hz
,
200Hz
,
...
,
20kHz
- in the case of vibration measurements,
BUFFER
selected in the
TRIGGER
position and
1/3 OCTAVE
function;
VECTRMS
- in the case of
vibration measurements and
VLM
or
FFT
function
o
VEC/SND, MAX
,
125Hz
,
250Hz
,
500Hz
,
...
,
16kHz
- in the case of sound measurements
BUFFER
selected in the
TRIGGER
position and
1/1 OCTAVE
function;
VEC/SNDMAX
,
125Hz
,
160Hz
,
200Hz
,
...
,
20kHz
- in the case of sound measurements,
BUFFER
selected in the
TRIGGER
position and
1/3 OCTAVE
function
LEVEL
(position); available
values of the triggering level
o
1.00mm/s
2
.. 10.0km/s
2
- in the case of vibration measurements (or
60dB .. 200dB
if the
reference level was set to
1 µm/s
2
and the
LOG
(logarithmic) scale was selected in the
DISPLAY SCALE
sub-list)
o
24dB .. 136dB
- in the case of sound measurements
§
PRE/POST TRIGGER
(sub-list); number of the records with the results saved in the buffer
before the triggering and after the moment in which the signal is below the desired level
•
PRE
(position); available number of records:
0 .. 50
•
POST
(position); available number of records:
0 .. 200
Summary of Contents for SVAN 948
Page 1: ...SVAN 948 SOUND AND VIBRATION DATA LOGGER USER S MANUAL SVANTEK Sp z o o WARSAW June 2004...
Page 19: ...SVAN 948 USER MANUAL 2 6 The view of the rear panel of the SVAN 948 instrument in 1 1 scale...
Page 25: ...SVAN 948 USER MANUAL 3 6 Control diagram of the INPUT list...
Page 28: ...SVAN 948 USER MANUAL 3 9 Control diagram of the DISPLAY list...
Page 30: ...SVAN 948 USER MANUAL 3 11 Control diagram of the FILE list...
Page 32: ...SVAN 948 USER MANUAL 3 13 Control diagram of the AUX FUNCTION list...
Page 36: ...SVAN 948 USER MANUAL 3 17...
Page 37: ...SVAN 948 USER MANUAL 3 18 Control diagram of the SETUP list...