![Svantek SVAN 948 User Manual Download Page 137](http://html1.mh-extra.com/html/svantek/svan-948/svan-948_user-manual_1409249137.webp)
SVAN 948 USER MANUAL
5 - 5
Selection of the weighted Filters - TOTAL VALUES
The
TOTAL VALUES
(path: MENU / DISPLAY / DISPLAY SETUP/ CHANNEL x / TOTAL VALUES)
sub-
list which is available only in
1/1 OCTAVE
or
1/3 OCTAVE
analysis; enables the user to select the
weighted filters. In order to enter this list one has to press the
<ENTER>
push-button on the inversely
displayed
TOTAL VALUES
text of the
DISPLAY SETUP/ CHANNEL x
list. The
TOTAL VALUES
sub-list
is closed and the instrument returns to the
CHANNEL x
list after pressing the
<ESC>
push-button.
The view of the display with the DISPLAY SETUP list, the TOTAL VALUES text highlighted
(path: MENU / DISPLAY / DISPLAY SETUP / CHANNEL x / TOTAL VALUES)
Selection of the Weighted Filters for the 1
st
profile - TOTAL 1
The
TOTAL 1
sub-list enables one to select the weighted filter to be used for the calculation of the
TOTAL
value in the first profile (
FILTER
). In the case of vibration measurements it is also possible to
determine the type (
TYPE
) of the filter and the calibration coefficient (
CAL. F.
). The
TOTAL 1
sub-list is
closed and the instrument returns to the
TOTAL VALUES
list after pressing the
<ESC>
push-button,
which ignores any changes in the positions of the sub-list or the
<ENTER>
push-button, which confirms
the changes.
v
FILTER:
(position); available values of the weighted filters:
o
in the case of sound measurements:
A
,
SUSR1
,
SUSR2
,
SUSR3
or any other sent to the unit
by means of the interface,
The view of the displays with the TOTAL 1 list opened in the case of sound measurements
o
in the case of vibration measurements:
HP
,
VUSR1
,
VUSR2
,
VUSR3
or any other sent to the
unit by means of the interface.
The view of the displays with the TOTAL 1 list opened in the case of vibration measurements
v
TYPE:
(position available only for vibration measurements); available values if
VUSR1
,
VUSR2
, or
VUSR3
was selected in the previous position:
ACC
,
VEL
and
DIL
; if the
HP
filter was selected this
position is not displayed.
The displays with the TOTAL 1 list opened in the case of vibration measurements; USER3 filter selected
Summary of Contents for SVAN 948
Page 1: ...SVAN 948 SOUND AND VIBRATION DATA LOGGER USER S MANUAL SVANTEK Sp z o o WARSAW June 2004...
Page 19: ...SVAN 948 USER MANUAL 2 6 The view of the rear panel of the SVAN 948 instrument in 1 1 scale...
Page 25: ...SVAN 948 USER MANUAL 3 6 Control diagram of the INPUT list...
Page 28: ...SVAN 948 USER MANUAL 3 9 Control diagram of the DISPLAY list...
Page 30: ...SVAN 948 USER MANUAL 3 11 Control diagram of the FILE list...
Page 32: ...SVAN 948 USER MANUAL 3 13 Control diagram of the AUX FUNCTION list...
Page 36: ...SVAN 948 USER MANUAL 3 17...
Page 37: ...SVAN 948 USER MANUAL 3 18 Control diagram of the SETUP list...