Description
Description
1.
1. Turn the
Turn the leakage tester
leakage tester ON from
ON from the power
the power switch (Pic
switch (Pic 1)
1)
2.
2. Check
Check the
the program/pressure
program/pressure settings
settings (check
(check nominal
nominal values)
values)
3.
3. Place th
Place the modul
e module unde
e underneath
rneath the tester
the tester sensor
sensor glass side
glass side up
up
4.
4. Lower the
Lower the sensor down
sensor down towards the
towards the glass until
glass until the yellow
the yellow sensor light
sensor light turns on.
turns on. The
The
yellow light should be on during the whole test
yellow light should be on during the whole test (pic 2)
(pic 2)
5.
5. Close
Close the
the leakage
leakage tester
tester dome
dome (Pic
(Pic 3)
3)
6.
6. After completing
After completing the test
the test successfully both ind
successfully both indicator lights
icator lights (I and
(I and II) should b
II) should be green
e green
to show the tested unit t
to show the tested unit t o be waterproof. In case one or
o be waterproof. In case one or both of the lights are yellow
both of the lights are yellow
or red the unit is leaking.
or red the unit is leaking.
7.
7. After the
After the test the dom
test the dome rises
e rises up. Lift the
up. Lift the sensor and
sensor and remove the
remove the tested unit
tested unit
8.
8. Report the
Report the repair in
repair in Service Log
Service Log using the
using the correct fault
correct fault code
code
Material
Material
safety
safety data
data
The
The nominal
nominal
and
and limit
limit
values
values
Measuring time: Automatic
Measuring time: Automatic
-0,4 / +0,5 bar
-0,4 / +0,5 bar
Tightness tolerance: 1,0 %
Tightness tolerance: 1,0 %
Shell analysis: Std
Shell analysis: Std
Quality
Quality
control
control
Indicator lights (I and II) are
Indicator lights (I and II) are green when a unit is waterproof and has passed
green when a unit is waterproof and has passed the test.
the test.
Other
Other
Protective stickers have to be removed during the
Protective stickers have to be removed during the test
test
In case a unit needs to
In case a unit needs to be retested immediately, the unit should be opened to
be retested immediately, the unit should be opened to allow the
allow the
inner pressure of the unit to normalize with
inner pressure of the unit to normalize with the exterior pressure in between the tests.
the exterior pressure in between the tests.
Humidity underneath the class, waterproofness tested ok:
Humidity underneath the class, waterproofness tested ok:
Condensation
Condensation inside a
inside a watch
watch is a
is a common ph
common phenomenon
enomenon (or a
(or a challenge)
challenge) in th
in the
e
watch industry
watch industry
What
What actually
actually happens
happens
-
-
Normal
Normal air alway
air always contains
s contains some amou
some amount of
nt of humidity
humidity which en
which ends up
ds up inside
inside the
the
watch in when it is
watch in when it is assembled in a factory or a repair center
assembled in a factory or a repair center
-
-
When the
When the watch i
watch is subject
s subject to a
to a rapid chan
rapid change of
ge of temperature (
temperature (e.g. jumping
e.g. jumping into
into
cold water in tropical environment) the humidity condenses on
cold water in tropical environment) the humidity condenses on the surface which
the surface which
cools down fastest, typically the lens.
cools down fastest, typically the lens.
-
-
The
The humidity
humidity disappears
disappears when
when the
the temperature
temperature differences
differences even
even out
out
Consequently
Consequently the level
the level of humid
of humidity needs
ity needs to be
to be controlled
controlled whenever
whenever the pr
the product is
oduct is
opened
opened
Condensation
Condensation can
can be tested
be tested with the
with the heat pla
heat plate test
te test in the
in the repair
repair centers
centers
Repair
Repair
instructions
instructions
Leakage
Leakage
test
test