Dispenser is leaking
product from the pump
body
1. Remove pump.
2. Return pump assembly to A. C. Dispensing
Equipment Inc. to be rebuilt.
Dispenser is not level
1. Check to make sure all four legs at the bottom
corners of the dispenser are in place.
2. Tighten any legs that are loose.
3. Make sure the legs are not bent.
4. Replace any bent or missing legs. Replacement
legs may be obtained from SureShot Dispensing
Systems® Technical Assistance Center at 1-888-
777-9990 or 1-902-865-9602.
5. For dispensers with adjustable legs, adjust legs
to level dispenser. Place a bubble level on top of the
dispenser to aid in the leveling process.
Red warning light at the
top of the product
selection button is
flashing
NOTE: The flashing red light is a warning light to
indicate that the volume in the flavor tank is getting low
and the flavor will need to be refilled soon. A solid red
warning light indicates the product has run out and must
be refilled or replaced.
1. Open the dispenser door.
2. Replace or refill the flavor tank, following the
instructions on pages 8 - 11.
3. Reset the tank level:
a. Close the dispenser door.
b. Press the Flavor selection button for the tank that
was filled.
c. Press the Reset button on the upper front door of
the dispenser.
The light should stop flashing or go out.
4. If the red light continues, call the SureShot
Dispensing Systems® Technical Assistance Center
at 1-888-777-9990 or 1-902-865-9602.
LCD Display on the
front door does not
come on
Check to make sure that the pumps are operating. If so,
the LCD may be faulty. If the pumps don’t function, and
the LCD Display is not on, the circuit breaker may have
tripped out and may need to be reset.
To Reset the circuit breaker:
1. Turn the power switch OFF.
2. Check the circuit breaker.
- Locate the Circuit Breaker on the lower left side of
the dispenser.