NOTE:
The PRIME function automatically tracks the amount of product
removed from the tank.
There is no need to refill the tank after priming it.
If you choose to refill the tank, you must reset the level, following
the procedure in the “Reset” section
9. Close the dispenser door. The dispenser is now ready to operate.
TO REMOVE AN EMPTY FLAVOR TANK
1. Place a container under the product dispensing block to catch any
residual flavor and to prevent spills.
2. Press the
Flavor
button for the tank to be removed
3. Before the red light on the Flavor button goes out, press and hold the
Clean
button for two seconds.
Allow the pump system to empty all residual product.
4. When the tank and pump are empty, press the
Clean
button again to
cancel the remainder of the clean cycle.
5. Open the dispenser door and slide the tank shelf forward.
6. Lift up the empty flavor tank out of the pump body and remove the tank.
7. Rinse, wash, rinse and sanitize the flavor tank. Follow Cleaning
Instructions on page 17.
8. Load a clean, sanitized tank, following Install and Fill instructions on
pages 8 and 9.
NOTE:
Always
clean empty tanks before re-using or storing them.
Follow the “Install, Fill & Prime Flavor Tanks” instructions on pages 8 and 9
when you place an empty tank in the dispenser