CHECK VALVE MAINTENANCE:
Fig 4 Remove check valve
Fig 5 Check valve – input
Fig 6 Check valve - output
To replace a check valve, if leaking:
a. turn the front half of the valve
housing in a counterclockwise
direction by ¼ rotation and
pull to remove. (Fig 4)
b. remove the check valve from
the valve housing.
Do not remove the O-rings
from either side of the valve
housing.
c. insert a new check valve in
the proper orientation to direct
flow, with the input end (Fig 5)
facing the flavor tank and the
output end (Fig 6) facing the
product dispensing block.
Check valve replacements are
available from SureShot
Dispensing Systems® Technical
Assistance Center
d. reattach the check valve
housing, making sure both O-
rings are still in place. Turn ¼
rotation clockwise while pushing
into the housing to secure the
fitting.