background image

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Table of Contents 

 

Safety 

Precautions    

 

Inspection for Damage   

 

  5 

Uncrating the Dispenser   

 

  5 

Reshipment 

     

 

Electrical 

Requirements 

   

 

Electrical 

Servicing    

 

Installation & Location of Dispenser    6 
Starting 

Dispenser 

    

 

Clean before Use   

 

 

  7 

Loading Dispenser 

 

 

  8 

 Install 

Tank 

    

 

 Fill 

Tank 

    

 

 

Prime Tank Pump   

 

  9 

Remove Empty Flavor Tank 

 

10 

Refill & Reset Flavor Tank 

 

11 

Operating 

Instructions 

  12 

 Button 

Panel   12 

 

To Dispense Flavor 

 

13 

 Drink 

Count 

Data 

  13 

Low 

Level 

Indicator   14 

Low 

Level 

Lockout   14 

LCD 

Display 

    15 

Cleaning 

    16 

 Dispenser 

Components 

 

          16 

 

Exterior 

 

 

 

16 

 

Product Dispense Block   

17 

 Catch 

Tray 

   17 

 

Flavor Tank – not in Dispenser  17 

 

Tank & Pump System 

 

18 

 Cleaning 

Schedule 

  20 

Maintenance – General   

 

20    

                       – Tube Maintenance 

20 

                       – Check Valve  

 

21 

Troubleshooting 

   22 

Warranty 

 

 

 

 

27 

 
Figures 
1.  FlavorShot 5 Dispenser 

 

  3 

2.  Loading Tanks   

 

 

  8 

3. 

 

Button 

Panel 

   12 

4.  Remove Check Valve   

 

21 

5.  Check Valve – input   

 

21 

6.  Check Valve – output   

 

21 

7.  Wiring Diagram  

 

 

26 

 
Tables 
1.  LCD Display 

 

 

 

15 

 

 

The AC-FS5 FlavorShot by 
SureShot™ provides efficient, 
accurate, sanitary dispensing of five 
flavor products from one easy-to-use 
dispenser. 
The dispenser delivers flavors in pre-
set, portion-controlled quantities 
using unique, patent-pending 
technology.   
 
General Features 
•  dispenses 5 flavors 
•  fast, easy, accurate portions 
•  standard or customized  
   programming of flavor portions 
   and flavor combinations 
•  infrared programmability for   
   flavor amounts 
•  patent-pending technology 
•  low level indication  
•  low level lockout 
•  special 

Non-Drip System 

  

 eliminates product waste and 

   countertop spills 
•  drink count data  
•  sanitary 
•  designed for up to 7.5” (19 cm) 
   cup height 
•  compact countertop design 
•  one year on-site warranty 

 

General Specifications 
•  A/C Supply Voltage: 120 VAC,  
   60 Hz, 1Ph, 15 Amp  
•  Stainless steel construction 

 

 
 
 
 
 

                  

  

 

 

 

  D-19-002 RevB

Summary of Contents for AC-FS5 FlavorShot

Page 1: ...AC FS5 Operations Manual FlavorShot by SureShot D 19 002 Rev B...

Page 2: ...5 Dispenser 3 2 Loading Tanks 8 3 Button Panel 12 4 Remove Check Valve 21 5 Check Valve input 21 6 Check Valve output 21 7 Wiring Diagram 26 Tables 1 LCD Display 15 The AC FS5 FlavorShot by SureShot...

Page 3: ...ATE 1 Place cup on catch tray 2 Press buttons for product desired bottom row select flavor middle row select modifier if required top row select size Capacity 5 x 950 ml tanks Weight 45 pounds empty d...

Page 4: ...2 mls etc The multi functional button panel enables you to dispense the correct amount for each of your cup sizes and your beverage recipes The flavors are stored in sanitary tanks within the dispens...

Page 5: ...may damage the dispenser To uncrate follow these instructions 1 Position the box with the This Side Up arrow pointing upward 2 Turn the dispenser box on its side 3 Remove the packaging material at th...

Page 6: ...t Inc before the service technician is dispatched Contact the SureShot Dispensing Systems Technical Assistance Center at 1 888 777 9990 or 1 902 865 9602 for approval The customer is responsible for a...

Page 7: ...he Power Switch ON The switch is recessed on the lower left side of the dispenser 3 The LCD window will display Wait and then a series of 5 dots will appear This indicates that all 5 tank pumps are op...

Page 8: ...om plastic tanks stored within the dispenser Flavors may be transferred from original containers into clean sanitized tanks which are loaded into the dispenser The flavor tanks sit in pumps which must...

Page 9: ...e tank filled Press the Reset button The LCD will display Reset Full or Reset Low Fill Press the Reset button until Reset Full is displayed CAUTION The accuracy of the low level indicator and lockout...

Page 10: ...on the Flavor button goes out press and hold the Clean button for two seconds Allow the pump system to empty all residual product 4 When the tank and pump are empty press the Clean button again to ca...

Page 11: ...t Full is displayed If you refill the tank to the Low level a Press the Flavor button for the tank filled b Press the Reset button The LCD will display Reset Full or Reset Low Fill Press the Reset but...

Page 12: ...spenser The flavor and volume to be dispensed are selected by pressing buttons on the Button Panel on the front door of the dispenser Press buttons as required BUTTON PANEL Fig 3 Button Panel FlavorSh...

Page 13: ...d hold for 2 seconds Release the Prime button 2 Press Clean button and hold for 2 seconds 3 Press the Flavor button for the flavor you want the Drink Count Data on e g French Vanilla 4 The LCD window...

Page 14: ...after 750 ml have been dispensed from the tank Note that approximately 200 ml of flavor is left to be dispensed from the tank when the light begins to flash Once the LED begins to flash the tank can b...

Page 15: ...tra Large indicates size selected Only S M and L are used at this time Refill Tank indicates tank must be filled to the Full line Reset Full indicates tank level is resetting to Full Reset Low Fill in...

Page 16: ...tion or if the Clean button is selected accidentally the cleaning cycle may be ended by selecting the Clean button a second time After cleaning and before installing flavor tanks apply a small amount...

Page 17: ...ay in the dishwasher and washing on the pot cycle 4 RINSE After washing rinse the tray well with lukewarm water 5 SANITIZE Sanitize the tray sanitizer using a mild sanitizer such as chlorine at 100 pp...

Page 18: ...mp system 1 Place a catch container under the product dispensing block to catch any residual flavor from the tank and pump 2 Press the Flavor button for the tank system to be cleaned 3 Before the red...

Page 19: ...r Press the Flavor button for the tank to be rinsed Before the red light on the Flavor button goes out press and hold the Clean button for 2 seconds Allow the water in the tank and pump system to run...

Page 20: ...s of the dispenser TUBE MAINTENANCE Check the dispense tubes periodically to ensure they are not blocked cut cracked or disfigured Damaged tubes must be replaced To replace the tube 1 remove the tube...

Page 21: ...Do not remove the O rings from either side of the valve housing c insert a new check valve in the proper orientation to direct flow with the input end Fig 5 facing the flavor tank and the output end F...

Page 22: ...kinks and are not pinched off 4 Make sure the dispensing tube block is clean 5 Prime the tank pump See page 9 6 Turn OFF the dispenser wait 10 seconds then turn the dispenser back ON This resets the...

Page 23: ...o replace inlet check valve a Empty flavor tank by pressing and holding the Clean button for two seconds and allowing the flavor to drain out b Lift flavor tank out c Loosen the plastic check valve re...

Page 24: ...ube a remove the tube from the barbed fittings at both ends b cut replacement tube to the length of the tube you are replacing c attach tube to the barbed fittings at each end 2 Make sure the flavor d...

Page 25: ...on button is flashing NOTE The flashing red light is a warning light to indicate that the volume in the flavor tank is getting low and the flavor will need to be refilled soon A solid red warning ligh...

Page 26: ...ct your problem or if you have other problems please contact the SureShot Dispensing Systems Technical Assistance Center at 1 888 777 9990 or 1 902 865 9602 if you are within the Warranty Period for y...

Page 27: ...or service performed by its Authorized Service Agencies The use of other than A C Dispensing Equipment Inc Authorized Service Agencies will void this warranty and A C Dispensing Equipment Inc will not...

Page 28: ...formed at overtime or premium labor rates Should service be required at times which normally involve overtime or premium labor rates the owner shall be charged for the difference between normal servic...