![Sur-Gard SG-System III Operating Manual Download Page 71](http://html1.mh-extra.com/html/sur-gard/sg-system-iii/sg-system-iii_operating-manual_1406547071.webp)
CHAPTER FIVE - ADVANCED PROGRAMMING
68
SG-Sys
tem I Operating Man
ual
5
4/2 format with account code 1234, alarm code 2 on zone 3. (1234-23)
NOTE: The first digit of the Contact ID event code will also follow option 7C/17C/27C.
For UL Listed products, the permitted setting is 00.
SG-DRL3 Option 7D: Audio Zone Code
SG-DRL3-2L Option 17D/27D: Audio Zone Code
Default (00)
Audio zone code is the range of zone codes that will activate audio. The first digit is the lowest code. The second digit indicates the highest
zone that will activate audio. Option 7D/17D/27D may be used with 10 to 40 Baud formats, DTMF 4/1, 4/2, and 4/3 formats.
NOTE: Option 7D/17D/27D Only works for DMP Serial 1 not for DMP Serial 3.
For UL Listed products, the permitted setting is 00.
SG-DRL3 Option 7E Audio RS-232
SG-DRL3-2L Option 17E/27E Audio RS-232
Default (00)
This is the code sent to the automation software that indicates that 2-way audio has been initiated. If this option is set to '00' there will be no
audio-initiated message sent to the automation output.
Option
7A
17A
27A
Option
7C
17C
27C
Switch Reason (or 7B/17B/27B) to Audio
00
1-1
2-3
00
1-2
3-5
1-4
1-2
00
00
3-4
3-4
1-3
1-5
Yes
Yes
No
No
No
No
Yes
Alarm code 2 falls within the code range 1-2.
Account code 1234 falls within the range 1-1.
Account code 1234 is outside the range 2-3.
Alarm code 2 is outside the range 3-4.
If both are programmed, both must be good and alarm code 2 is outside the
range 3-4.
Both must be good and account code 1234 is outside the range 3-5.
Alarm code 2 falls within the code range 1-5, account code 1234 falls within
the range 1-4.
Setting
Description
Automation Output
00
2-way audio message disabled
No Automation Output
01
Outputs automation message with protocol "S
Send SRRLLL[#AAAA|NLFssoo][DC4]
02
Outputs automation message with protocol "O
Send 0RRLLL[#AAAA|NLFssoo][DC4]
05
Outputs automation message with protocol "S"
and adds RRLL to the message as clear text
Send SRRLLL[#AAAA|NLFssoo*RRLL*][DC4]
06
Outputs automation message with protocol "O"
and adds RRLL to the message as clear text
Send 0RRLLL[#AAAA|NLFssoo*RRLL*][DC4]
09
Outputs automation message with protocol "S"
and adds the dialed phone number for the call
transfer
SRRLLL[#AAAA|NLFssoo*#NNNNNNNNNNNNNNNN*][DC4]
Summary of Contents for SG-System III
Page 22: ...Line Card In This Chapter Standby Mode on page 19 Line Fault on page 21...
Page 92: ...In this Chapter Options 00 47 on page 90 SG DRL3 IP Programming...
Page 100: ...Printer Words...
Page 105: ...Telco Connector Pin Outs...
Page 107: ...DEC HEX BIN Conversion Chart...
Page 109: ...ASCII Character Chart...
Page 111: ...SG DRL3 SG DRL3E SG DRL3 2L Communication Formats...
Page 113: ...Ports...
Page 115: ...Events Messages...
Page 124: ...Glossary...