45
Step2: Dump the partial or all materials in the weighing hopper into a packing bag, then stop the
dumping process. After the real-time weight being stable, press
【
LossEnd
】
to get
AD1 Value
.
Step3: Weigh the actual weight of the materials in the packing bag on a high-accuracy weigher, then
press the button
【
Weight
】
to input the weight value as ‘Calibrating Weight’.
Step4: Press
【
Save
】
to display and save the new ‘Span Coefficient’ value. If the dumping weight [the
weight of the materials dumped from the weighing hopper] is too small, the operation
【
Save
】
will be
invalid.
Sign
Data
Sign
Data
Big Digits
Real-time Weight [Weight Unit].
Motion
Stable
Weight is dynamic changing.
Weight is stable.
Span Coeff
The saved ‘Span
Coefficient’ value.
AD Value
Real-time AD Value of weighing
signal.
Cal. Weight
Calibrating Weight = Dumping Weight
AD0 Value
The AD Value after Feeding ended.
AD1 Value
The AD Value after Dumping ended.