12
3.5.2 Prompt Message
3.5.3 Error Message
Message
Alarm Cause
Solution
Target Batch
Finished
Alarm or Auto-stop with ‘Target
Batch Finished’ or ‘Target Weight
Finished’.
Refer to parameter [203] ‘Target Batch Count’,
[204] ‘Target Batch Weight’ and [301] ‘Target
Batch Control’.
Last Batch
It’s in the packing process of the last
batch.
The message will disappear after the present batch
finished.
ZERO Invalid
Over ‘Zero Fine Adjusting Range’.
Refer to parameter [123] ‘Zero Fine Adjusting
Range’.
Message
Alarm Cause
Solution
RAM Fault
The chip RAM is damaged.
Replace the chip RAM.
EEPROM Fault
The chip EEPROM is damaged.
Replace the chip EEPROM.
Parameter Error
The chip EEPROM is damaged.
Replace the chip EEPROM.
Weighing Signal
Error
Weighing signal reversed or not
connected.
Connect the loadcell correctly.
ADC Fault
The chip ADC is damaged.
Replace the ADC module.
Over ADC Range
Weighing signal exceeds A/D
conversion range.
1. Check if the loadcell is connected.
2. Check if the capacity of loadcell is too small.
3. Check if the loading weight is too big.
Overload Alarm
Weight > (Scale Ca 9 ×
Scale Division).
1 . Check if the set value of parameter [102]
‘Scale Capacity’ is reasonable.
2. Check if the loadcell is connected.
3. Check if the capacity of loadcell is too small.
4. Check if the loading weight is too big.
Internal Data-bus
Fault
Please contact manufacturer.