31
6.3.4 Working Mode Parameters
No.
Sign
Range
Default
Description
REG
300
Application
Mode
0~3
3
[*]
Application Mode
0: APP1 Single-scale Mode
1: APP2 Double-scale Mode
2: APP3 Three-scale Mode
3: APP4 Four-scale Mode
Authorization: Administrator.
40301
301
Target Batch
Control
0~1
0
Target Batch [Count/Weight] Control
0: OFF
1: ON
[With Target Batch Count finished or
Target Batch Weight finished, the packing process
will stop automatically]
40303
302
Auto Zero Cycle
Interval
0~99
10
Auto Zero Cycle Interval
Set value=0: No doing ‘Auto Zero Fine
Adjustment’.
Set value > 0: To the first two batches after ‘Start’
signal inputted, the controller will do ‘Auto Zero
Fine Adjustment’ [without power-down protection]
before feeding; then to the next batch, only after
Batch Count reached to this set value, the controller
will do ‘Auto Zero Fine Adjustment’ before
feeding.
40305
303
Packing Mode
0~1
0
Packing Mode
0: Combination [Multi-hopper Packing]
1: Combination [Single-hopper Packing]
2: Respective [Single-hopper Packing]
Authorization: Administrator.
40307
304
DO Feeding’s
Start Mode
0~2
0
DO Feeding’s Start Mode
0: Together [SP1&SP2&SP3]
1: In Order [SP1-SP2-SP3]
2: SoftStart [SP2&SP1&SP3]
40309
305
SP3 Low-speed
Feeding Mode
0~1
0
SP3 Low-speed Feeding Mode
0: Continuous
[Continuous Feeding Mode]
1: Inching
[Inching Feeding Mode: SP3 works with
Inching Feeding Mode in Low-speed Feeding
process. Inching DO outputs ON/OFF; Inching AO
outputs 0V/‘Control Voltage for SP3 Low-speed
Feeding’]
40311
306
t1 SP3 ON
Holding Time
0.03
~9.99
0.50
t1 SP3 ON Holding Time
[s]
Used for SP3 Inching Feeding Mode.
40313