28
No.
Sign
Range
Default
Description
REG
108
Stablity Judging
Range
0~99
0
Stablity Judging Range
[d: Division]
Weight Variance per [109] ‘Stablity Judging
Time’ being within [108] ‘Stablity Judging
Range’ means ‘Weight is stable’.
40125
109
Stablity Judging
Time
0.1~9.9
1.0
Stablity Judging Time
[s]
40127
110
SP1&SP2
Anti-vibration
Filter1
0~19
3
[13]
SP1&SP2 Anti-vibration Filter1
Filter1 is used for setpoint control of SP1
High-speed Feeding & SP2 Medium-speed
Feeding.
40129
111
SP3
Anti-vibration
Filter2
0~19
17
SP3 Anti-vibration Filter2
Filter2 is used for setpoint control of SP3
Low-speed Feeding and stable weight display.
40131
Demand:
Filter2’s 10
0
Digit
≥
Filter1’s 10
0
Digit + 2
Filter1&2’s
10
0
Digit Set
Set Value
Cutoff Frequency
0
None
1
11.2Hz
2
8.0Hz
3
5.6Hz
4
4.0Hz
5
2.8Hz
6
2.0Hz
7
1.4Hz
8
1.0Hz
9
0.7Hz
Filter1&2’s
10
1
Digit Set
Set Value
Anti-Vibration Grade
0
Medium
1
High
112
Weight Display
Smooth Filter3
1~80
20
Weight Display Smooth Filter3
The bigger set value of Filter3 will make the
real-time weight more stable with slower
response speed.
40133