23
4.4.3 Working Timing Diagram
T1: Delay After Clamping Bag
T2: Delay to Auto ZERO
T3: T3 Delay to Auto-feed
T4: No Comparing Time
T5: Delay to Stabilize Weight
T6: Max. Dumping Gate Opening Time
T7: Delay to Close Dumping Gate
T8a: Max. Dumping Gate Closing Time
T8b: Delay to Release Bag
Target - Fall
Weight
Target Value
Time
Non-load Zero Range
Positive Deviation
Negative Deviation
Target - SP2 Lead
Target - SP1 Lead
Auto/Manual
AUTO
START
T2
T3
High-speed Feed
1_SP1
Medium-speed Feed
1_SP2
Low-speed Feed
1_SP3
T4
T5
Deviation
1_ALARM
Feeding Ended
FD_END
T6
Dumping
1_DUMP
T7
T8a
Bag-clamp Request
BAG_I
T1
T8b
Clamp Bag
BAG
ON: Auto State
Auto Zero Fine Adjustment [Optional]
ON: Clamp Bag