D-14
X7SBA User's Manual
Rebuilding Arrays
Note 1:
Rebuilding applies to Fault Tolerant array (RAID 1) only.
If an array Build process is interrupted or when one critical member is missing,
you must perform a Rebuild to restore its functionality. For a critical array rebuild
operation, the optimal drive is the source drive.
Note 2:
If no spare array exists and a hard disk drive fails, you need to create a
spare before you can rebuild an array.
To Rebuild an array:
1 From the Main Menu, select Manage Arrays (as shown in the screen below).
From the List of Arrays, select the array you want to rebuild.
2 Press <Ctrl> and <R> to rebuild.
Summary of Contents for X7SBA
Page 1: ...X7SBA USER S MANUAL Revision 1 0...
Page 76: ...4 26 X7SBA User s Manual Notes...
Page 82: ...A 6 X7SBA User s Manual Notes...
Page 88: ...B 6 X7SBA User s Manual Notes...
Page 126: ...E 4 X7SBA User s Manual Notes...