7-20
S
UPER
S
ERVER 6026T-TF User's Manual
Event Sensor Type
•
Event Sensor Number,
•
Event Dir Type
•
Event Data.
•
Clear BMC System Event Log
Select OK and press the <Enter> key to clear the BMC system log. Select Cancel
to keep the BMC System log. The options are
OK
and Cancel.
Caution
: Any cleared information is unrecoverable. Make absolutely sure
that you no longer need any data stored in the log before clearing the
BMC Event Log.
X
Set LAN Confi guration
Set this feature to confi gure the IPMI LAN adapter with a network address as shown
in the following graphics.
Channel Number
Enter the channel number for the SET LAN Confi guration command. It is initially
set to
[1]
. Press <+> or <-> on your keyboard to change the Channel Number.
Channel Number Status
This feature displays the channel status for the Channel Number selected above:
"Channel Number is OK" or "Wrong Channel Number".
X
IP Address Confi guration
This submenu displays the following IP Address Confi guration information.
Parameter Selector
This item displays the parameter of your IP Address confi guration.
IP Address Source
This feature allows the user to determine how an IP address is assigned to this
device. Select DHCP (Dynamic Host Confi guration Protocol) to allow this device
to obtain an IP address from a DHCP server, which manages a pool of IP ad-
dresses and network information on a "request and grant" basis. Upon time-out
(or lease expiration), the IP address assigned to the client can be re-assigned
to a new client.) Select
Static
(Static Allocation) to manually enter an IP address
based on a pre-determined range of addresses (usually assigned by a network
Summary of Contents for SUPERSERVER 6026T-TF
Page 1: ...SUPERSERVER 6026T TF SUPER USER S MANUAL 1 0...
Page 5: ...Notes Preface v...
Page 28: ...SUPERSERVER 6026T TF User s Manual 3 4 Notes...
Page 58: ...5 26 SUPERSERVER 6026T TF User s Manual Notes...
Page 68: ...6 10 SUPERSERVER 6026T TF Manual Notes...
Page 100: ...A 2 SUPERSERVER 6026T TF User s Manual Notes...