Figure 5-6: Installing into a Rack
Standard Chassis Installation
Installing the Chassis into a Rack
1. Con
fi
rm that the inner rails are properly installed on the chassis.
2. Con
fi
rm that the outer rails are correctly installed on the rack.
3. Pull the middle rail out from the front of the outer rail and make sure that the
ball-bearing shuttle is at the front locking position of the middle rail.
4. Align the chassis inner rails with the front of the middle rails.
5. Slide the inner rails on the chassis into the middle rails, keeping the pressure
even on both sides, until the locking tab of the inner rail clicks into the front of
the middle rail, locking the chassis into the fully extended position.
6. Depress the locking tabs of both sides at the same time and push the chassis
all the way into the rear of the rack.
7. If necessary for security purposes, use screws to secure the chassis handles
to the front of the rack.
Ball-Bearing
Shuttle
Stability hazard. The rack stabilizing mechanism must be in place, or the
rack must be bolted to the
fl
oor before you slide the unit out for servicing.
Failure to stabilize the rack can cause the rack to tip over.
Note:
fi
gures are for illustrative purposes only. Always install servers into racks
from the bottom up.
Summary of Contents for SuperServer 4048B-TRFT
Page 1: ...SUPER USER S MANUAL Revision 1 0a SuperServer 4048B TRFT...
Page 5: ...v SUPERSERVER 4048B TRFT USER S MANUAL Notes...
Page 24: ...2 10 SUPERSERVER 4048B TRFT USER S MANUAL Notes...
Page 48: ...4 20 SUPERSERVER 4048B TRFT USER S MANUAL Notes...
Page 80: ...5 32 SUPERSERVER 4048B TRFT USER S MANUAL Notes...
Page 90: ...6 10 SUPERSERVER 4048B TRFT USER S MANUAL Notes...
Page 142: ...7 52 SUPERSERVER 4048B TRFT USER S MANUAL Notes...
Page 144: ...A 2 SUPERSERVER 4048B TRFT USER S MANUAL Notes...