ERVER 2026T-6RFT+/2026T-6F+ User's Manual
5-3 Connecting
Cables
Now that the processors are installed, the next step is to connect the cables to
the serverboard.
Connecting Data Cables
The cables used to transfer data from the peripheral devices have been carefully
routed in precon
fi
gured systems to prevent them from blocking the
fl
ow of cooling
air that moves through the system from front to back. If you need to disconnect any
of these cables, you should take care to reroute them as they were originally after
reconnecting them (make sure the red wires connect to the pin 1 locations). If you
are con
fi
guring the system, keep the air
fl
ow in mind when routing the cables.
The following data cables (with their connector locations noted) should be connect-
ed. See the serverboard layout diagram in this chapter for connector locations.
•
DVD-ROM drive cable (SATA0)
•
SAS cables (SAS0 ~ SAS7)
•
Control Panel cable (JF1, see next page)
Connecting Power Cables
The X8DTU-6TF+/X8DTU-6F+ has a 24-pin primary power supply connector des-
ignated "JPW1" for connection to the ATX power supply. Connect the appropriate
connector from the power supply to JPW1 to supply power to the serverboard.
See the Connector De
fi
nitions section in this chapter for power connector pin
de
fi
nitions.
In addition, your power supply must be connected to the 8-pin Processor Power
connectors at JPW2 and JPW3.
Connecting the Control Panel
JF1 contains header pins for various front control panel connectors. See Figure 5-1
for the pin locations of the front control panel buttons and LED indicators. Please
note that even and odd numbered pins are on opposite sides of each header.
All JF1 wires have been bundled into single keyed ribbon cable to simplify their
connection. The red wire in the ribbon cable plugs into pin 1 of JF1. Connect the
other end of the cable to the Control Panel printed circuit board, located just behind
the system status LEDs in the chassis.
See the Connector De
fi
nitions section in this chapter for details and pin descrip-
tions of JF1.
Summary of Contents for SUPERSERVER 2026T-6RF+
Page 1: ...SUPERSERVER 2026T 6RFT 2026T 6RF SUPER USER S MANUAL 1 0a...
Page 5: ...v Preface Notes...
Page 23: ...Chapter 2 Server Installation 2 9 1 4 1 4 Figure 2 5 Securing the Chassis to the Rack...
Page 30: ...3 4 SUPERSERVER 2026T 6RFT 6RF User s Manual Notes...
Page 50: ...4 20 SUPERSERVER 2026T 6RFT 2026T 6F User s Manual Notes...
Page 90: ...6 10 SUPERSERVER 2026T 6RFT 6RF User s Manual Figure 6 8 Removing the Power Supply Release Tab...
Page 120: ...7 30 SUPERSERVER 2026T 6RFT 2026T 6F User s Manual Notes...
Page 122: ...A 2 SUPERSERVER 1026T 6RFT 1026T 6F User s Manual Notes...