5-2 Processor and Heatsink Installation
IMPORTANT!
Always connect the power cord last and remove it
fi
rst before add-
ing, removing or changing any hardware components. Make sure that you install
the processor into the CPU socket
before
you install the heatsink and fan. The
X8DTU-6TF+/X8DTU-6F+ can support either one or two processors. If installing
one processor only, install it into the CPU1 socket.
Note:
When purchasing a CPU or when receiving a serverboard with a CPU pre-installed,
make sure that the CPU plastic cap is in place and none of the CPU pins are bent;
otherwise, contact the retailer immediately.
Warning:
When handling the processor, avoid placing direct pressure on the label
area of the fan. Also, do not place the serverboard on a conductive surface, which can
damage the BIOS battery and prevent the system from booting up.
1. Starting with CPU1, press the
socket clip to release the load
plate, which covers the CPU
socket, from its locked position.
2. Gently lift the socket clip to open
the load plate.
3. Hold the plastic cap at its north
and south center edges to remove
it from the CPU socket.
Note
: The photos on this page and
succeeding pages are for illustration
purposes only. They do not necessarily
re
fl
ect the exact product(s) described
in this manual.
Socket Clip
Load Plate
Plastic Cap
Holding the north & south edges
Installing LGA1366 Processors
Summary of Contents for SUPERSERVER 2026T-6RF+
Page 1: ...SUPERSERVER 2026T 6RFT 2026T 6RF SUPER USER S MANUAL 1 0a...
Page 5: ...v Preface Notes...
Page 23: ...Chapter 2 Server Installation 2 9 1 4 1 4 Figure 2 5 Securing the Chassis to the Rack...
Page 30: ...3 4 SUPERSERVER 2026T 6RFT 6RF User s Manual Notes...
Page 50: ...4 20 SUPERSERVER 2026T 6RFT 2026T 6F User s Manual Notes...
Page 90: ...6 10 SUPERSERVER 2026T 6RFT 6RF User s Manual Figure 6 8 Removing the Power Supply Release Tab...
Page 120: ...7 30 SUPERSERVER 2026T 6RFT 2026T 6F User s Manual Notes...
Page 122: ...A 2 SUPERSERVER 1026T 6RFT 1026T 6F User s Manual Notes...