6-8
S
UPER
S
ERVER 2026T-6RFT+/6RF+ User's Manual
DVD-ROM Drive Installation
The top cover of the chassis must be opened to gain full access to the DVD-ROM
drive bay. The 2026T-6RFT+/6RF+ accomodates only slim-line DVD-ROM drives.
Side mounting brackets are needed to mount a slim-line DVD-ROM drive in the
2026T-6RFT+/6RF+ server. You must power down the system before installing or
removing a DVD-ROM drive.
Removing/Installing a Drive
1. With the chassis cover removed, unplug the power and data cables from the
drive you want to remove.
2. Locate the locking tab at the rear of the drive. It will be on the left side of the
drive when viewed from the front of the chassis.
3. Pull the tab away from the drive and push the drive unit out the front of the
chassis.
4. Add a new drive by following this procedure in reverse order. You may hear a
faint *click* of the locking tab when the drive is fully inserted.
5. Remember to reconnect the data and power cables to the drive before replac-
ing the chassis cover and restoring power to the system.
Hard Drive Backplane
The hard drives plug into a backplane that provides power and drive ID. A RAID
controller can be used with the backplane to provide data security. The operating
system you use must have RAID support to enable the hot-swap capability of the
drives. The backplane is already precon
fi
gured, so there are no jumpers or switches
present on it.
Warning:
Regardless of how many hard drives are installed, all drive carriers must
remain in the drive bays to maintain proper air
fl
ow.
Warning:
Use caution when working around the hard drive backplane. Do not touch the
backplane with any metal objects and make sure no ribbon cables touch the backplane
or obstruct the holes, which aid in proper air
fl
ow.
Summary of Contents for SUPERSERVER 2026T-6RF+
Page 1: ...SUPERSERVER 2026T 6RFT 2026T 6RF SUPER USER S MANUAL 1 0a...
Page 5: ...v Preface Notes...
Page 23: ...Chapter 2 Server Installation 2 9 1 4 1 4 Figure 2 5 Securing the Chassis to the Rack...
Page 30: ...3 4 SUPERSERVER 2026T 6RFT 6RF User s Manual Notes...
Page 50: ...4 20 SUPERSERVER 2026T 6RFT 2026T 6F User s Manual Notes...
Page 90: ...6 10 SUPERSERVER 2026T 6RFT 6RF User s Manual Figure 6 8 Removing the Power Supply Release Tab...
Page 120: ...7 30 SUPERSERVER 2026T 6RFT 2026T 6F User s Manual Notes...
Page 122: ...A 2 SUPERSERVER 1026T 6RFT 1026T 6F User s Manual Notes...