3-2
S
UPER
S
TORAGE
S
YSTEM 6047R-E1R36L User's Manual
Power Fail
Indicates a power supply module has failed. The second power supply module will
take the load and keep the system running but the failed module will need to be
replaced. Refer to Chapter 6 for details on replacing the power supply. This LED
should be off when the system is operating normally.
Overheat/Fan Fail
When this LED
fl
ashes, it indicates a fan failure. When on continuously it indicates
an overheat condition, which may be caused by cables obstructing the air
fl
ow in
the system or the ambient room temperature being too warm. Check the routing of
the cables and make sure all fans are present and operating normally. You should
also check to make sure that the chassis covers are installed. Finally, verify that
the heatsinks are installed properly (see Chapter 5). This LED will remain
fl
ashing
or on as long as the indicated condition exists.
NIC1
Indicates network activity on the LAN1 port when
fl
ashing.
NIC2
Indicates network activity on the LAN2 port when
fl
ashing.
1
2
Summary of Contents for 6047R-E1R36L
Page 1: ...SUPER STORAGE SYSTEM 6047R E1R36L SUPER USER S MANUAL 1 0...
Page 5: ...Notes Preface v...
Page 26: ...3 4 SUPERSTORAGESYSTEM 6047R E1R36L User s Manual Notes...
Page 62: ...5 32 SUPERSTORAGESYSTEM 6047R E1R36L User s Manual Notes...
Page 108: ...A 2 SUPERSTORAGESYSTEM 6047R E1R36L User s Manual Notes...