YSTEM 6047R-E1R36L User's Manual
Figure 2-5. Installing the Rack Rails
1
A
1
B
Installing the Chassis into a Rack
Installing the Chassis into a Rack
1. Con
fi
rm that chassis includes the inner rails (A), also con
fi
rm that the outer
rails (B) are installed on the rack.
2. Align chassis rails (A) with the front of the rack rails (B).
3. Slide the chassis rails into the rack rails, keeping the pressure even on both
sides (you may have to depress the locking tabs when inserting). When the
server has been pushed completely into the rack, you should hear the locking
tabs "click" into the locked position.
4. Tighten up all the screws on the front side and rear side of both outer rails.
5. (Optional) Insert and tightening the thumbscrews that hold the front of the
server to the rack.