Chapter 7: BIOS
7-11
Slot1 PCI-X 133MHz, Slot2 PCI-X 100 MHz ZCR, Slot3 PCI-Exp x8,
Slot4 PCI-Exp x4, Slot5 PCI-Exp x4, and Slot6 PCI-Exp x8
Access the submenu for each of the settings above to make changes to the
following:
Option ROM Scan
When enabled, this setting will initialize the device expansion ROM. The options
are
Enabled
and Disabled.
Enable Master
This setting allows you to enable the selected device as the PCI bus master.
The options are
Enabled
and Disabled.
Latency Timer
This setting allows you to set the clock rate for Bus Master. A high-priority, high-
throughout device may benefi t from a greater clock rate. The options are
Default
,
0020h, 0040h, 0060h, 0080h, 00A0h, 00C0h, and 00E0h. For Unix, Novell and
other Operating Systems, please select the option: other. If a drive fails after
the installation of a new software, you might want to change this setting and
try again. A different OS requires a different Bus Master clock rate
.
Large Disk Access Mode
This setting determines how large hard drives are to be accessed. The options are
DOS
or Other (for Unix, Novelle NetWare and other operating systems).
Advanced Chipset Control
Access the submenu to make changes to the following settings.
Warning
: Exercise caution when changing the Advanced settings.
Incorrect values entered may cause system malfunction. Also, a
very high DRAM frequency or incorrect DRAM timing may cause
system instability. When this occurs, revert to the default setting.
SERR Signal Condition
This setting specifi es the ECC Error conditions that an SERR# is to be asserted.
The options are None,
Single Bit
, Multiple Bit, and Both.
4GB PCI Hole Granularity
This feature allows you to select the granularity of PCI hole for PCI slots. If MTRRs
are not enough, this option may be used to reduce MTRR occupation. The options
are:
256 MB
, 512 MB, 1GB and 2GB.
!
Summary of Contents for SUPERSERVER 6015X-3
Page 1: ...SUPERSERVER 6015X 3 SUPERSERVER 6015X T SUPERSERVER 6015X 8 USER S MANUAL 1 0a SUPER...
Page 5: ...v Preface Notes...
Page 10: ...Notes x SUPERSERVER 6015X 3 6015X T 6015X 8 User s Manual...
Page 23: ...Chapter 2 Server Installation 2 7 Figure 2 3 Installing the Server into a Rack...
Page 25: ...Chapter 2 Server Installation 2 9 Figure 2 4 Accessing the Inside of the System...
Page 100: ...A 6 SUPERSERVER 6015X 3 6015X T 6015X 8 User s Manual Notes...
Page 106: ...B 6 SUPERSERVER 6015X 3 6015X T 6015X 8 User s Manual Notes...
Page 140: ...C 34 SUPERSERVER 6015X 3 6015X T 6015X 8 User s Manual Notes...
Page 144: ...D 4 SUPERSERVER 6015X T 6015X 8 User s Manual Notes...